Association of venous volume and diameter of incompetent perforator veins in the lower limb - Implications for perforator vein surgery
(2005) In European Journal of Vascular and Endovascular Surgery 30(6). p.670-673- Abstract
- Purpose. To define the association between venous volume as measured with air-plethysmography and the duplex ultrasound measured diameter of incompetent perforator of the lower limb. Patients and methods. Thirty-six patients with chronic venous disease were investigated with air-plethysmography and duplex ultrasound. Venous volume and venous filling time was measured. Venous filling index was calculated. The findings were correlated with the diameter of the largest incompetent perforator vein of the lower limb. Results. Twenty-six patients with venous volume in the normal range (80-170 ml) had a median perforator diameter of 3. 5 non (IQR 3.2-4.3). Ten patients with venous volume above 170 ml had median perforator diameter of 5.5 mm (lQR... (More)
- Purpose. To define the association between venous volume as measured with air-plethysmography and the duplex ultrasound measured diameter of incompetent perforator of the lower limb. Patients and methods. Thirty-six patients with chronic venous disease were investigated with air-plethysmography and duplex ultrasound. Venous volume and venous filling time was measured. Venous filling index was calculated. The findings were correlated with the diameter of the largest incompetent perforator vein of the lower limb. Results. Twenty-six patients with venous volume in the normal range (80-170 ml) had a median perforator diameter of 3. 5 non (IQR 3.2-4.3). Ten patients with venous volume above 170 ml had median perforator diameter of 5.5 mm (lQR 4.6-7.7). (p=0.001, Mann-Whitney). There was a correlation between the venous volume and diameter of the largest incompetent perforator vein. (Pearson correlation factor 0.69, p=0.01). Conclusion. Limb volume correlates to the diameter of the largest incompetent perforator of the calf. Increase in venous limb volume could be partly responsible for an increase in the size of calf perforators thereby promoting incompetence. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/894264
- author
- Danielsson, Gudmundur LU ; Eklof, B and Kistner, RL
- publishing date
- 2005
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- duplex ultrasound, venous volume, plethysmography, chronic venous disease, incompetent perforator veins
- in
- European Journal of Vascular and Endovascular Surgery
- volume
- 30
- issue
- 6
- pages
- 670 - 673
- publisher
- Elsevier
- external identifiers
-
- wos:000234162400019
- pmid:16055354
- scopus:28944446260
- ISSN
- 1532-2165
- DOI
- 10.1016/j.ejvs.2005.06.015
- language
- English
- LU publication?
- no
- additional info
- The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Emergency medicine/Medicine/Surgery (013240200)
- id
- 1695254d-c5ca-42a5-8fe1-8e0582f950f7 (old id 894264)
- date added to LUP
- 2016-04-01 16:28:22
- date last changed
- 2023-02-21 09:36:04
@article{1695254d-c5ca-42a5-8fe1-8e0582f950f7, abstract = {{Purpose. To define the association between venous volume as measured with air-plethysmography and the duplex ultrasound measured diameter of incompetent perforator of the lower limb. Patients and methods. Thirty-six patients with chronic venous disease were investigated with air-plethysmography and duplex ultrasound. Venous volume and venous filling time was measured. Venous filling index was calculated. The findings were correlated with the diameter of the largest incompetent perforator vein of the lower limb. Results. Twenty-six patients with venous volume in the normal range (80-170 ml) had a median perforator diameter of 3. 5 non (IQR 3.2-4.3). Ten patients with venous volume above 170 ml had median perforator diameter of 5.5 mm (lQR 4.6-7.7). (p=0.001, Mann-Whitney). There was a correlation between the venous volume and diameter of the largest incompetent perforator vein. (Pearson correlation factor 0.69, p=0.01). Conclusion. Limb volume correlates to the diameter of the largest incompetent perforator of the calf. Increase in venous limb volume could be partly responsible for an increase in the size of calf perforators thereby promoting incompetence.}}, author = {{Danielsson, Gudmundur and Eklof, B and Kistner, RL}}, issn = {{1532-2165}}, keywords = {{duplex ultrasound; venous volume; plethysmography; chronic venous disease; incompetent perforator veins}}, language = {{eng}}, number = {{6}}, pages = {{670--673}}, publisher = {{Elsevier}}, series = {{European Journal of Vascular and Endovascular Surgery}}, title = {{Association of venous volume and diameter of incompetent perforator veins in the lower limb - Implications for perforator vein surgery}}, url = {{http://dx.doi.org/10.1016/j.ejvs.2005.06.015}}, doi = {{10.1016/j.ejvs.2005.06.015}}, volume = {{30}}, year = {{2005}}, }