Spatiotemporal QRST cancellation techniques for analysis of atrial fibrillation

Stridh, Martin LU and Sörnmo, Leif LU (2001) In IEEE Transactions on Biomedical Engineering 48(1). p.105-111
Abstract
A new method for QRST cancellation is presented for the analysis of atrial fibrillation in the surface electrocardiogram (ECG). The method is based on a spatiotemporal signal model which accounts for dynamic changes in QRS morphology caused, e.g., by variations in the electrical axis of the heart. Using simulated atrial fibrillation signals added to normal ECGs, the results show that the spatiotemporal method performs considerably better than does straightforward average beat subtraction (ABS). In comparison to the ABS method, the average QRST-related error was reduced to 58 percent. The results obtained from ECGs with atrial fibrillation agreed very well with those from simulated fibrillation signals.
Please use this url to cite or link to this publication:
author
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
IEEE Transactions on Biomedical Engineering
volume
48
issue
1
pages
105 - 111
publisher
IEEE--Institute of Electrical and Electronics Engineers Inc.
external identifiers
  • scopus:0035110101
ISSN
0018-9294
DOI
10.1109/10.900266
language
English
LU publication?
yes
id
0fd3075e-0e8f-47da-ad03-12a95b25b333 (old id 1746330)
date added to LUP
2010-12-16 15:58:42
date last changed
2017-09-17 08:44:07
@article{0fd3075e-0e8f-47da-ad03-12a95b25b333,
  abstract     = {A new method for QRST cancellation is presented for the analysis of atrial fibrillation in the surface electrocardiogram (ECG). The method is based on a spatiotemporal signal model which accounts for dynamic changes in QRS morphology caused, e.g., by variations in the electrical axis of the heart. Using simulated atrial fibrillation signals added to normal ECGs, the results show that the spatiotemporal method performs considerably better than does straightforward average beat subtraction (ABS). In comparison to the ABS method, the average QRST-related error was reduced to 58 percent. The results obtained from ECGs with atrial fibrillation agreed very well with those from simulated fibrillation signals.},
  author       = {Stridh, Martin and Sörnmo, Leif},
  issn         = {0018-9294},
  language     = {eng},
  number       = {1},
  pages        = {105--111},
  publisher    = {IEEE--Institute of Electrical and Electronics Engineers Inc.},
  series       = {IEEE Transactions on Biomedical Engineering},
  title        = {Spatiotemporal QRST cancellation techniques for analysis of atrial fibrillation},
  url          = {http://dx.doi.org/10.1109/10.900266},
  volume       = {48},
  year         = {2001},
}