Sobocinski, Jonathan ; Dias, Nuno V. LU orcid ; Hongku, Kiattisak ; Lombardi, Joseph V. ; Zhou, Qing ; Saunders, Alan T. ; Resch, Timothy LU and Haulon, Stéphan (2020) In Journal of Vascular Surgery 71(2). p.2-407
Abstract

Objective: The objective of this study was to compare short-term outcomes in patients who underwent thoracic endovascular aortic repair (TEVAR) with stent grafts alone or with a composite device design (stent graft plus bare-metal aortic stent) for acute type B aortic dissection in the setting of malperfusion. Methods: This retrospective analysis included patients with acute (≤14 days of symptom onset) complicated type B dissection in the setting of malperfusion who were treated with stent grafts alone (TEVAR cohort) at two European institutions vs those who underwent TEVAR with a composite device design (Cook Medical, Bloomington, Ind) in the investigational STABLE I feasibility study and STABLE II pivotal study (STABLE cohort).... (More)

Objective: The objective of this study was to compare short-term outcomes in patients who underwent thoracic endovascular aortic repair (TEVAR) with stent grafts alone or with a composite device design (stent graft plus bare-metal aortic stent) for acute type B aortic dissection in the setting of malperfusion. Methods: This retrospective analysis included patients with acute (≤14 days of symptom onset) complicated type B dissection in the setting of malperfusion who were treated with stent grafts alone (TEVAR cohort) at two European institutions vs those who underwent TEVAR with a composite device design (Cook Medical, Bloomington, Ind) in the investigational STABLE I feasibility study and STABLE II pivotal study (STABLE cohort). Preoperative characteristics and 30-day outcomes (including mortality, malperfusion-related mortality, morbidity, and secondary interventions) were compared between the two groups. Results: The TEVAR cohort (41 patients; mean age, 58.8 ± 12.7 years; 78.0% male) and the STABLE cohort (84 patients; mean age, 57.8 ± 11.7 years; 71.4% male) were largely similar in preoperative medical characteristics, with more STABLE patients presenting with a history of hypertension (79.8% vs 58.5%; P = .018). The TEVAR and STABLE groups had similar lengths of dissection (451.8 ± 112.7 mm vs 411.8 ± 116.4 mm; P = .10) and similar proximal and distal extent of dissection. At presentation, the two groups exhibited comparable organ system involvement in malperfusion: renal (53.7% TEVAR, 57.1% STABLE), gastrointestinal (41.5% TEVAR, 44.0% STABLE), lower extremities (34.1% TEVAR, 52.4% STABLE), and spinal cord (9.8% TEVAR, 2.4% STABLE). The 30-day rate of all-cause mortality was 17.1% (7/41) in the TEVAR group and 8.3% (7/84) in the STABLE group (P = .22). The 30-day rate of malperfusion-related mortality (deaths from bowel/mesenteric ischemia or multiple organ failure) was 12% (5/41) in the TEVAR group and 2.4% (2/84) in the STABLE group (P = .038). The 30-day morbidity, for the TEVAR and STABLE groups, respectively, included bowel ischemia (9.8% [4/41] vs 2.4% [2/84]; P = .09), renal failure requiring dialysis (7.3% [3/41] vs 9.5% [8/84]; P > .99), paraplegia or paraparesis (4.9% [2/41] vs 3.6% [3/84]; P = .66), and stroke (2.4% [1/41] vs 10.7% [9/84]; P = .16). The occurrence of 30-day secondary intervention was similar in the TEVAR and STABLE groups (7.3% [3/41] vs 7.1% [6/84]; P > .99). True lumen expansion in the abdominal aorta was significantly greater in the STABLE group. Conclusions: In patients with acute type B aortic dissection in the setting of branch vessel malperfusion, the use of a composite device with proximal stent grafts and distal bare aortic stent appeared to result in lower malperfusion-related mortality than the use of stent grafts alone. The 30-day rates of morbidity and secondary interventions were similar between the groups.

(Less)
Please use this url to cite or link to this publication:
author
; ; ; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Aorta, Bare stent, Dissection, Malperfusion, TEVAR, Type B
in
Journal of Vascular Surgery
volume
71
issue
2
pages
2 - 407
publisher
Mosby-Elsevier
external identifiers
  • pmid:31280979
  • scopus:85068256384
ISSN
0741-5214
DOI
10.1016/j.jvs.2019.04.478
language
English
LU publication?
yes
id
17e85637-45bc-4a2b-ba0e-911c61b19032
date added to LUP
2019-07-10 16:19:42
date last changed
2024-11-14 14:13:29
@article{17e85637-45bc-4a2b-ba0e-911c61b19032,
  abstract     = {{<p>Objective: The objective of this study was to compare short-term outcomes in patients who underwent thoracic endovascular aortic repair (TEVAR) with stent grafts alone or with a composite device design (stent graft plus bare-metal aortic stent) for acute type B aortic dissection in the setting of malperfusion. Methods: This retrospective analysis included patients with acute (≤14 days of symptom onset) complicated type B dissection in the setting of malperfusion who were treated with stent grafts alone (TEVAR cohort) at two European institutions vs those who underwent TEVAR with a composite device design (Cook Medical, Bloomington, Ind) in the investigational STABLE I feasibility study and STABLE II pivotal study (STABLE cohort). Preoperative characteristics and 30-day outcomes (including mortality, malperfusion-related mortality, morbidity, and secondary interventions) were compared between the two groups. Results: The TEVAR cohort (41 patients; mean age, 58.8 ± 12.7 years; 78.0% male) and the STABLE cohort (84 patients; mean age, 57.8 ± 11.7 years; 71.4% male) were largely similar in preoperative medical characteristics, with more STABLE patients presenting with a history of hypertension (79.8% vs 58.5%; P = .018). The TEVAR and STABLE groups had similar lengths of dissection (451.8 ± 112.7 mm vs 411.8 ± 116.4 mm; P = .10) and similar proximal and distal extent of dissection. At presentation, the two groups exhibited comparable organ system involvement in malperfusion: renal (53.7% TEVAR, 57.1% STABLE), gastrointestinal (41.5% TEVAR, 44.0% STABLE), lower extremities (34.1% TEVAR, 52.4% STABLE), and spinal cord (9.8% TEVAR, 2.4% STABLE). The 30-day rate of all-cause mortality was 17.1% (7/41) in the TEVAR group and 8.3% (7/84) in the STABLE group (P = .22). The 30-day rate of malperfusion-related mortality (deaths from bowel/mesenteric ischemia or multiple organ failure) was 12% (5/41) in the TEVAR group and 2.4% (2/84) in the STABLE group (P = .038). The 30-day morbidity, for the TEVAR and STABLE groups, respectively, included bowel ischemia (9.8% [4/41] vs 2.4% [2/84]; P = .09), renal failure requiring dialysis (7.3% [3/41] vs 9.5% [8/84]; P &gt; .99), paraplegia or paraparesis (4.9% [2/41] vs 3.6% [3/84]; P = .66), and stroke (2.4% [1/41] vs 10.7% [9/84]; P = .16). The occurrence of 30-day secondary intervention was similar in the TEVAR and STABLE groups (7.3% [3/41] vs 7.1% [6/84]; P &gt; .99). True lumen expansion in the abdominal aorta was significantly greater in the STABLE group. Conclusions: In patients with acute type B aortic dissection in the setting of branch vessel malperfusion, the use of a composite device with proximal stent grafts and distal bare aortic stent appeared to result in lower malperfusion-related mortality than the use of stent grafts alone. The 30-day rates of morbidity and secondary interventions were similar between the groups.</p>}},
  author       = {{Sobocinski, Jonathan and Dias, Nuno V. and Hongku, Kiattisak and Lombardi, Joseph V. and Zhou, Qing and Saunders, Alan T. and Resch, Timothy and Haulon, Stéphan}},
  issn         = {{0741-5214}},
  keywords     = {{Aorta; Bare stent; Dissection; Malperfusion; TEVAR; Type B}},
  language     = {{eng}},
  number       = {{2}},
  pages        = {{2--407}},
  publisher    = {{Mosby-Elsevier}},
  series       = {{Journal of Vascular Surgery}},
  title        = {{Thoracic endovascular aortic repair with stent grafts alone or with a composite device design in patients with acute type B aortic dissection in the setting of malperfusion}},
  url          = {{http://dx.doi.org/10.1016/j.jvs.2019.04.478}},
  doi          = {{10.1016/j.jvs.2019.04.478}},
  volume       = {{71}},
  year         = {{2020}},
}