Low energy soft x-ray emission spectrometer at BL-09A in NewSUBARU
(2016) 12th International Conference on Synchrotron Radiation Instrumentation, SRI 2015 In AIP Conference Proceedings 1741.- Abstract
A compact soft X-ray emission spectrometer for the energy region of 50-600 eV has been designed and constructed for the long undulator beamline BL-09A in the NewSUBARU synchrotron radiation (SR) facility. The optical design of the spectrometer is based on a grazing incidence flat-field spectrometer using a valid line-spacing grating. The average groove density of the grating is 2000 L/mm, and the angle of incidence to the grating is 86.5 deg. The distances from the slit to the grating and from the grating to the CCD are 355 mm and 650 mm, respectively. The energy resolution, E/ΔE, was estimated to be greater than 1000 in the energy range of 50-600 eV. Spectra of K-emission X-rays of several light elements, such as B, C, N, and O, from... (More)
A compact soft X-ray emission spectrometer for the energy region of 50-600 eV has been designed and constructed for the long undulator beamline BL-09A in the NewSUBARU synchrotron radiation (SR) facility. The optical design of the spectrometer is based on a grazing incidence flat-field spectrometer using a valid line-spacing grating. The average groove density of the grating is 2000 L/mm, and the angle of incidence to the grating is 86.5 deg. The distances from the slit to the grating and from the grating to the CCD are 355 mm and 650 mm, respectively. The energy resolution, E/ΔE, was estimated to be greater than 1000 in the energy range of 50-600 eV. Spectra of K-emission X-rays of several light elements, such as B, C, N, and O, from various samples were successfully obtained.
(Less)
- author
- Niibe, Masahito and Tokushima, Takashi LU
- publishing date
- 2016-07-27
- type
- Chapter in Book/Report/Conference proceeding
- publication status
- published
- subject
- host publication
- Proceedings of the 12th International Conference on Synchrotron Radiation Instrumentation, SRI 2015
- series title
- AIP Conference Proceedings
- editor
- Shen, Qun and Nelson, Christie
- volume
- 1741
- article number
- 030042
- pages
- 4 pages
- publisher
- American Institute of Physics (AIP)
- conference name
- 12th International Conference on Synchrotron Radiation Instrumentation, SRI 2015
- conference location
- New York, United States
- conference dates
- 2015-07-06 - 2015-07-10
- external identifiers
-
- scopus:84984585771
- ISSN
- 1551-7616
- 0094-243X
- ISBN
- 9780735413986
- DOI
- 10.1063/1.4952865
- language
- English
- LU publication?
- no
- additional info
- Publisher Copyright: © 2016 Author(s).
- id
- 1ac98ad0-2de4-402c-8c62-e4c790255a5c
- date added to LUP
- 2021-11-23 08:59:57
- date last changed
- 2024-04-06 14:29:57
@inproceedings{1ac98ad0-2de4-402c-8c62-e4c790255a5c, abstract = {{<p>A compact soft X-ray emission spectrometer for the energy region of 50-600 eV has been designed and constructed for the long undulator beamline BL-09A in the NewSUBARU synchrotron radiation (SR) facility. The optical design of the spectrometer is based on a grazing incidence flat-field spectrometer using a valid line-spacing grating. The average groove density of the grating is 2000 L/mm, and the angle of incidence to the grating is 86.5 deg. The distances from the slit to the grating and from the grating to the CCD are 355 mm and 650 mm, respectively. The energy resolution, E/ΔE, was estimated to be greater than 1000 in the energy range of 50-600 eV. Spectra of K-emission X-rays of several light elements, such as B, C, N, and O, from various samples were successfully obtained.</p>}}, author = {{Niibe, Masahito and Tokushima, Takashi}}, booktitle = {{Proceedings of the 12th International Conference on Synchrotron Radiation Instrumentation, SRI 2015}}, editor = {{Shen, Qun and Nelson, Christie}}, isbn = {{9780735413986}}, issn = {{1551-7616}}, language = {{eng}}, month = {{07}}, publisher = {{American Institute of Physics (AIP)}}, series = {{AIP Conference Proceedings}}, title = {{Low energy soft x-ray emission spectrometer at BL-09A in NewSUBARU}}, url = {{http://dx.doi.org/10.1063/1.4952865}}, doi = {{10.1063/1.4952865}}, volume = {{1741}}, year = {{2016}}, }