Digital luminescence radiography using a chest phantom : Comparison between radiographs displayed on monitor and hard-copy

Kehler, M. ; Albrechtsson, U. LU ; Arnadóttir, E. ; Ebbesen, A. ; Hochbergs, P. LU ; Lundin, A. LU ; Lyttkens, K. LU ; Kheddache, K. ; Månsson, L. G. and Angelhed, J. E. (1992) In Acta Radiologica 33(2). p.117-122
Abstract

Ninety-eight digital radiographs of a chest phantom with simulated tumors in the mediastinum and left lung and a pneumothoraxsimulation in the right hemithorax were compared with the corresponding examinations saved on optical disk and viewed on a 1000-line monitor. The examinations were reviewed by 7 radiologists with different experience, and receiver operating characteristic (ROC) curves were constructed. There was no significant difference between the hard-copy and the monitor results. A significant interobserver difference was seen only with the low attenuating 6 mm "tumor" and then only between the observer with the highest and the one with the lowest scores.

Please use this url to cite or link to this publication:
author
; ; ; ; ; ; ; ; and
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Phantoms, Radiography, digital, Receiver operating characteristic (ROC) curve, Thorax
in
Acta Radiologica
volume
33
issue
2
pages
117 - 122
publisher
SAGE Publications
external identifiers
  • pmid:1562402
  • scopus:0026596660
ISSN
0284-1851
DOI
10.1080/02841859209173143
language
English
LU publication?
no
id
1b9d73bc-8b6e-4e96-9557-566883b52bb9
date added to LUP
2019-05-28 22:26:43
date last changed
2024-01-01 08:16:20
@article{1b9d73bc-8b6e-4e96-9557-566883b52bb9,
  abstract     = {{<p>Ninety-eight digital radiographs of a chest phantom with simulated tumors in the mediastinum and left lung and a pneumothoraxsimulation in the right hemithorax were compared with the corresponding examinations saved on optical disk and viewed on a 1000-line monitor. The examinations were reviewed by 7 radiologists with different experience, and receiver operating characteristic (ROC) curves were constructed. There was no significant difference between the hard-copy and the monitor results. A significant interobserver difference was seen only with the low attenuating 6 mm "tumor" and then only between the observer with the highest and the one with the lowest scores.</p>}},
  author       = {{Kehler, M. and Albrechtsson, U. and Arnadóttir, E. and Ebbesen, A. and Hochbergs, P. and Lundin, A. and Lyttkens, K. and Kheddache, K. and Månsson, L. G. and Angelhed, J. E.}},
  issn         = {{0284-1851}},
  keywords     = {{Phantoms; Radiography, digital; Receiver operating characteristic (ROC) curve; Thorax}},
  language     = {{eng}},
  month        = {{01}},
  number       = {{2}},
  pages        = {{117--122}},
  publisher    = {{SAGE Publications}},
  series       = {{Acta Radiologica}},
  title        = {{Digital luminescence radiography using a chest phantom : Comparison between radiographs displayed on monitor and hard-copy}},
  url          = {{http://dx.doi.org/10.1080/02841859209173143}},
  doi          = {{10.1080/02841859209173143}},
  volume       = {{33}},
  year         = {{1992}},
}