Technique for testing the patency of laser iridotomies
(1986) In Acta Ophthalmologica 64(3). p.3-251- Abstract
With laser iridotomy it may often be difficult to achieve total penetration of the iris, particularly in very light or very dark irides. It may be impossible to determine with the slit-lamp whether a small laser iridotomy is functionally penetrating. We describe a straightforward method to test iridotomies for aqueous flow patency. Transcorneally introduced fluorescein is used to delineate any aqueous bulk flow from the posterior to the anterior chamber.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/1ccd6ce6-3fdc-4b1b-86bb-107bbffee526
- author
- Heijl, A LU and Holm, O
- publishing date
- 1986-06
- type
- Contribution to journal
- publication status
- published
- keywords
- Aqueous Humor/physiology, Fluorescent Dyes, Humans, Iris/surgery, Laser Therapy, Pigment Epithelium of Eye/surgery
- in
- Acta Ophthalmologica
- volume
- 64
- issue
- 3
- pages
- 3 pages
- publisher
- Wiley-Blackwell
- external identifiers
-
- pmid:3751510
- scopus:0022486772
- ISSN
- 0001-639X
- DOI
- 10.1111/j.1755-3768.1986.tb06912.x
- language
- English
- LU publication?
- no
- id
- 1ccd6ce6-3fdc-4b1b-86bb-107bbffee526
- date added to LUP
- 2019-06-30 16:28:39
- date last changed
- 2025-01-09 18:19:47
@article{1ccd6ce6-3fdc-4b1b-86bb-107bbffee526, abstract = {{<p>With laser iridotomy it may often be difficult to achieve total penetration of the iris, particularly in very light or very dark irides. It may be impossible to determine with the slit-lamp whether a small laser iridotomy is functionally penetrating. We describe a straightforward method to test iridotomies for aqueous flow patency. Transcorneally introduced fluorescein is used to delineate any aqueous bulk flow from the posterior to the anterior chamber.</p>}}, author = {{Heijl, A and Holm, O}}, issn = {{0001-639X}}, keywords = {{Aqueous Humor/physiology; Fluorescent Dyes; Humans; Iris/surgery; Laser Therapy; Pigment Epithelium of Eye/surgery}}, language = {{eng}}, number = {{3}}, pages = {{3--251}}, publisher = {{Wiley-Blackwell}}, series = {{Acta Ophthalmologica}}, title = {{Technique for testing the patency of laser iridotomies}}, url = {{http://dx.doi.org/10.1111/j.1755-3768.1986.tb06912.x}}, doi = {{10.1111/j.1755-3768.1986.tb06912.x}}, volume = {{64}}, year = {{1986}}, }