Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

On sizing of flow meters used in customer accounting devices in district heating systems

Ari, Ingimundarson ; Janusz, Wollerstrand and Arvastson, Lars LU (1998) 9th Int. Conf. Flow Measurements, FLOWMEKO'98
Abstract
The paper deals with accuracy problems when

heat energy consumption in district heating (DH) systems

is calculated by measuring the DH water

ow rate and its

cooling. An investigation on the in

uence that sizing of

ow

meters used has on the accuracy of DH water

ow mea-

surements in a typical DH subscriber station is presented.

Furthermore the consequences of the choice of

ow meter

size on energy metering accuracy is studied. The goal is to

determine rules leading to optimal sizing of the

ow meters.
Please use this url to cite or link to this publication:
author
; and
organization
publishing date
type
Chapter in Book/Report/Conference proceeding
publication status
published
subject
keywords
Dimensioning, Flow Meter, District Heating
host publication
Proceedings 9th International Conference on Flow Measurement : FLOMEKO '98, June 15-17, 1998, Lund, Sweden
pages
6 pages
conference name
9th Int. Conf. Flow Measurements, FLOWMEKO'98
conference location
Lund, Sweden
conference dates
1998-06-15 - 1998-06-17
ISBN
91-630-6991-1
language
English
LU publication?
yes
id
1ef16e6b-13fd-405e-9db1-fa5d115691e1 (old id 1273187)
alternative location
http://www.ees.energy.lth.se/fileadmin/ees/Publikationer/1998/dhsizing.pdf
date added to LUP
2016-04-04 14:41:14
date last changed
2018-11-21 21:21:42
@inproceedings{1ef16e6b-13fd-405e-9db1-fa5d115691e1,
  abstract     = {{The paper deals with accuracy problems when<br/><br>
heat energy consumption in district heating (DH) systems<br/><br>
is calculated by measuring the DH water <br/><br>
ow rate and its<br/><br>
cooling. An investigation on the in<br/><br>
uence that sizing of <br/><br>
ow<br/><br>
meters used has on the accuracy of DH water <br/><br>
ow mea-<br/><br>
surements in a typical DH subscriber station is presented.<br/><br>
Furthermore the consequences of the choice of <br/><br>
ow meter<br/><br>
size on energy metering accuracy is studied. The goal is to<br/><br>
determine rules leading to optimal sizing of the <br/><br>
ow meters.}},
  author       = {{Ari, Ingimundarson and Janusz, Wollerstrand and Arvastson, Lars}},
  booktitle    = {{Proceedings 9th International Conference on Flow Measurement : FLOMEKO '98, June 15-17, 1998, Lund, Sweden}},
  isbn         = {{91-630-6991-1}},
  keywords     = {{Dimensioning; Flow Meter; District Heating}},
  language     = {{eng}},
  title        = {{On sizing of flow meters used in customer accounting devices in district heating systems}},
  url          = {{http://www.ees.energy.lth.se/fileadmin/ees/Publikationer/1998/dhsizing.pdf}},
  year         = {{1998}},
}