Advanced

The short rotators do not influence capsular compliance or pain in severe hip osteoarthritis. A randomised controlled trial.

Tarasevicius, Sarunas LU ; Loiba, Valdemaras and Wingstrand, Hans LU (2011) In HIP International 21(3). p.299-302
Abstract
Abstract: A randomised controlled trial was performed to investigate if the short rotators affected the compliance of the capsule in osteoarthritis (OA). 68 OA patients admitted for total hip arthroplasty (THA) were randomised to have their compliance estimated during surgery with either their short rotators intact or released. Radiographic severity of OA, range of motion and pain were assessed in the affected hip before surgery. There was no significant difference in the compliance of the capsule whether the short rotators were intact or released (p= 0.5). Furthermore, there was no significant correlation between pain and capsular compliance (p=0.4 and p=0.5). We found no significant effect of the short rotators on compliance of the hip... (More)
Abstract: A randomised controlled trial was performed to investigate if the short rotators affected the compliance of the capsule in osteoarthritis (OA). 68 OA patients admitted for total hip arthroplasty (THA) were randomised to have their compliance estimated during surgery with either their short rotators intact or released. Radiographic severity of OA, range of motion and pain were assessed in the affected hip before surgery. There was no significant difference in the compliance of the capsule whether the short rotators were intact or released (p= 0.5). Furthermore, there was no significant correlation between pain and capsular compliance (p=0.4 and p=0.5). We found no significant effect of the short rotators on compliance of the hip joint capsule, and no significant correlation between pain and capsular compliance. (Less)
Please use this url to cite or link to this publication:
author
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
HIP International
volume
21
issue
3
pages
299 - 302
publisher
Wichtig Editore
external identifiers
  • wos:000293505100006
  • pmid:21698578
  • scopus:79959523508
ISSN
1724-6067
DOI
10.5301/HIP.2011.8391
language
English
LU publication?
yes
id
9cadb863-f618-464b-8fb5-b88c1be6e7cd (old id 2007807)
alternative location
http://www.ncbi.nlm.nih.gov/pubmed/21698578?dopt=Abstract
date added to LUP
2011-07-06 10:53:00
date last changed
2017-01-01 07:29:36
@article{9cadb863-f618-464b-8fb5-b88c1be6e7cd,
  abstract     = {Abstract: A randomised controlled trial was performed to investigate if the short rotators affected the compliance of the capsule in osteoarthritis (OA). 68 OA patients admitted for total hip arthroplasty (THA) were randomised to have their compliance estimated during surgery with either their short rotators intact or released. Radiographic severity of OA, range of motion and pain were assessed in the affected hip before surgery. There was no significant difference in the compliance of the capsule whether the short rotators were intact or released (p= 0.5). Furthermore, there was no significant correlation between pain and capsular compliance (p=0.4 and p=0.5). We found no significant effect of the short rotators on compliance of the hip joint capsule, and no significant correlation between pain and capsular compliance.},
  author       = {Tarasevicius, Sarunas and Loiba, Valdemaras and Wingstrand, Hans},
  issn         = {1724-6067},
  language     = {eng},
  number       = {3},
  pages        = {299--302},
  publisher    = {Wichtig Editore},
  series       = {HIP International},
  title        = {The short rotators do not influence capsular compliance or pain in severe hip osteoarthritis. A randomised controlled trial.},
  url          = {http://dx.doi.org/10.5301/HIP.2011.8391},
  volume       = {21},
  year         = {2011},
}