Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Estimating transport parameters in an undisturbed soil column using time domain reflectometry and transfer function theory

Persson, Magnus LU and Berndtsson, Ronny LU orcid (1998) In Journal of Hydrology 205(3-4). p.232-247
Abstract
Modelling solute transport in the unsaturated zone is a complex problem given the inherent soil heterogeneity. Using time domain reflectometry (TDR) as described in this paper can improve data quality to be used in predictive models. The TDR technique requires appropriate calibration if it is to be used for solute concentration measurements under constant and varying water content. Two ways of determining the parameters in the relationship between bulk soil electrical conductivity, σa, soil solution electrical conductivity, σw and volumetric water content, θ, were used. Among the two calibration methods tested here, the one which involved eluting the soil with several pore volumes of water of known electrical conductivity under transient... (More)
Modelling solute transport in the unsaturated zone is a complex problem given the inherent soil heterogeneity. Using time domain reflectometry (TDR) as described in this paper can improve data quality to be used in predictive models. The TDR technique requires appropriate calibration if it is to be used for solute concentration measurements under constant and varying water content. Two ways of determining the parameters in the relationship between bulk soil electrical conductivity, σa, soil solution electrical conductivity, σw and volumetric water content, θ, were used. Among the two calibration methods tested here, the one which involved eluting the soil with several pore volumes of water of known electrical conductivity under transient flow conditions in an undisturbed soil column gave a linear σw−σa−θ relationship with depth dependent parameters. The other calibration method involved the use of disturbed soil under static conditions and resulted in a curvilinear σw−σa−θ relationship. The former calibration was subsequently used to determine solute concentrations in breakthrough experiments. Two solute transport experiments were carried out in the same undisturbed soil column; one for steady-state and one for transient flow condition. Parameters of the convective log normal transfer function (CLT) model were determined using time-integral-normalized resident concentrations. It was shown that the stochastic-convective approach described the experimental data well. Horizontal heterogeneity was more important during the transient experiment, where the topsoil was periodically ponded during a short period, than in the steady-state experiment, where unsaturated conditions were maintained throughout the experiment. This increased heterogeneity during transient flow was also reflected by the fact that preferential solute flow was only observed in the column's outlet under transient conditions. (Less)
Please use this url to cite or link to this publication:
author
and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Journal of Hydrology
volume
205
issue
3-4
pages
232 - 247
publisher
Elsevier
external identifiers
  • scopus:0032032788
  • wos:000073298300006
ISSN
0022-1694
DOI
10.1016/S0022-1694(97)00151-0
language
English
LU publication?
yes
id
21c23d46-e6e9-4f3e-b0da-ee9ac085b395
date added to LUP
2018-05-30 09:40:10
date last changed
2022-10-23 01:29:19
@article{21c23d46-e6e9-4f3e-b0da-ee9ac085b395,
  abstract     = {{Modelling solute transport in the unsaturated zone is a complex problem given the inherent soil heterogeneity. Using time domain reflectometry (TDR) as described in this paper can improve data quality to be used in predictive models. The TDR technique requires appropriate calibration if it is to be used for solute concentration measurements under constant and varying water content. Two ways of determining the parameters in the relationship between bulk soil electrical conductivity, σa, soil solution electrical conductivity, σw and volumetric water content, θ, were used. Among the two calibration methods tested here, the one which involved eluting the soil with several pore volumes of water of known electrical conductivity under transient flow conditions in an undisturbed soil column gave a linear σw−σa−θ relationship with depth dependent parameters. The other calibration method involved the use of disturbed soil under static conditions and resulted in a curvilinear σw−σa−θ relationship. The former calibration was subsequently used to determine solute concentrations in breakthrough experiments. Two solute transport experiments were carried out in the same undisturbed soil column; one for steady-state and one for transient flow condition. Parameters of the convective log normal transfer function (CLT) model were determined using time-integral-normalized resident concentrations. It was shown that the stochastic-convective approach described the experimental data well. Horizontal heterogeneity was more important during the transient experiment, where the topsoil was periodically ponded during a short period, than in the steady-state experiment, where unsaturated conditions were maintained throughout the experiment. This increased heterogeneity during transient flow was also reflected by the fact that preferential solute flow was only observed in the column's outlet under transient conditions.}},
  author       = {{Persson, Magnus and Berndtsson, Ronny}},
  issn         = {{0022-1694}},
  language     = {{eng}},
  number       = {{3-4}},
  pages        = {{232--247}},
  publisher    = {{Elsevier}},
  series       = {{Journal of Hydrology}},
  title        = {{Estimating transport parameters in an undisturbed soil column using time domain reflectometry and transfer function theory}},
  url          = {{http://dx.doi.org/10.1016/S0022-1694(97)00151-0}},
  doi          = {{10.1016/S0022-1694(97)00151-0}},
  volume       = {{205}},
  year         = {{1998}},
}