4D dosimetry and its applications to pre-treatment quality control and real-time in vivo dosimetry of VMAT treatments
(2013) 7th International Conference on 3D Radiation Dosimetry (IC3DDose) 444. p.012021-012021- Abstract
- In this study, a 4D dosimetry concept was developed. This concept included a method for calculation of 3D reference absorbed dose matrices at every control point of the delivery using a clinical treatment planning system (TPS). Further, the gamma evaluation method was extended to incorporate the 4th dimension of the TPS calculated dose distributions. The applications of the 4D dosimetry concept on pre-treatment quality control and real-time in vivo dosimetry were investigated.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/4027082
- author
- Nordström, Fredrik LU ; af Wetterstedt, S. and Bäck, Sven LU
- organization
- publishing date
- 2013
- type
- Chapter in Book/Report/Conference proceeding
- publication status
- published
- subject
- host publication
- 7th International Conference on 3D Radiation Dosimetry (IC3DDose)
- volume
- 444
- pages
- 012021 - 012021
- publisher
- IOP Publishing
- conference name
- 7th International Conference on 3D Radiation Dosimetry (IC3DDose)
- conference location
- Sydney, Australia
- conference dates
- 2012-11-04 - 2012-11-08
- external identifiers
-
- wos:000322968600021
- scopus:84883407254
- ISSN
- 1742-6596
- 1742-6588
- DOI
- 10.1088/1742-6596/444/1/012021
- language
- English
- LU publication?
- yes
- id
- 2d45d092-510e-400a-ac2a-8ca231a978ac (old id 4027082)
- date added to LUP
- 2016-04-01 10:25:23
- date last changed
- 2024-01-06 16:11:51
@inproceedings{2d45d092-510e-400a-ac2a-8ca231a978ac, abstract = {{In this study, a 4D dosimetry concept was developed. This concept included a method for calculation of 3D reference absorbed dose matrices at every control point of the delivery using a clinical treatment planning system (TPS). Further, the gamma evaluation method was extended to incorporate the 4th dimension of the TPS calculated dose distributions. The applications of the 4D dosimetry concept on pre-treatment quality control and real-time in vivo dosimetry were investigated.}}, author = {{Nordström, Fredrik and af Wetterstedt, S. and Bäck, Sven}}, booktitle = {{7th International Conference on 3D Radiation Dosimetry (IC3DDose)}}, issn = {{1742-6596}}, language = {{eng}}, pages = {{012021--012021}}, publisher = {{IOP Publishing}}, title = {{4D dosimetry and its applications to pre-treatment quality control and real-time in vivo dosimetry of VMAT treatments}}, url = {{http://dx.doi.org/10.1088/1742-6596/444/1/012021}}, doi = {{10.1088/1742-6596/444/1/012021}}, volume = {{444}}, year = {{2013}}, }