Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Design of a portable large spectral range grazing incidence instrument

Nordgren, J. and Nyholm, R. (1986) In Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment 246(1-3). p.242-245
Abstract

A design of a small size grazing incidence instrument is presented, which offers large spectral range and high resolution without sacrificing luminosity. The instrument is particularly suited for use at synchrotron radiation sources since it can be conveniently attached to existing experiment chambers. The basic idea of the design is the use of fixed mounted gratings of diffent radii and groove densities and a big two-dimensional position sensitive detector mounted on a x-y angle table. The design is discussed in some detail and performance is presented.

Please use this url to cite or link to this publication:
author
and
publishing date
type
Contribution to journal
publication status
published
in
Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment
volume
246
issue
1-3
pages
4 pages
publisher
Elsevier
external identifiers
  • scopus:0022063430
ISSN
0168-9002
DOI
10.1016/0168-9002(86)90081-1
language
English
LU publication?
no
id
30263d32-2c9d-486e-9913-b8f30b8f67be
date added to LUP
2016-08-19 11:14:14
date last changed
2021-09-26 03:36:58
@article{30263d32-2c9d-486e-9913-b8f30b8f67be,
  abstract     = {{<p>A design of a small size grazing incidence instrument is presented, which offers large spectral range and high resolution without sacrificing luminosity. The instrument is particularly suited for use at synchrotron radiation sources since it can be conveniently attached to existing experiment chambers. The basic idea of the design is the use of fixed mounted gratings of diffent radii and groove densities and a big two-dimensional position sensitive detector mounted on a x-y angle table. The design is discussed in some detail and performance is presented.</p>}},
  author       = {{Nordgren, J. and Nyholm, R.}},
  issn         = {{0168-9002}},
  language     = {{eng}},
  month        = {{05}},
  number       = {{1-3}},
  pages        = {{242--245}},
  publisher    = {{Elsevier}},
  series       = {{Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment}},
  title        = {{Design of a portable large spectral range grazing incidence instrument}},
  url          = {{http://dx.doi.org/10.1016/0168-9002(86)90081-1}},
  doi          = {{10.1016/0168-9002(86)90081-1}},
  volume       = {{246}},
  year         = {{1986}},
}