SU-8 Cantilever for Bio/chemical Sensing; Fabrication, Characterisation and Development of Novel Read-out Methods
(2008) In Sensors 8(3). p.1595-1612- Abstract
- Here, we present the activities within our research group over the last five yearswith cantilevers fabricated in the polymer SU-8. We believe that SU-8 is an interestingpolymer for fabrication of cantilevers for bio/chemical sensing due to its simple processingand low Young’s modulus. We show examples of different integrated read-out methodsand their characterisation. We also show that SU-8 cantilevers have a reduced sensitivity tochanges in the environmental temperature and pH of the buffer solution. Moreover, weshow that the SU-8 cantilever surface can be functionalised directly with receptormolecules for analyte detection, thereby avoiding gold-thiol chemistry.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/3130342
- author
- Nordström, Maria LU ; Keller, Stephan ; Lillemose, Michael ; Johansson, Alicia ; Dohn, Søren ; Haefliger, Daniel ; Blagoi, Gabriela ; Havsteen-Jakobsen, Mogens and Boisen, Anja
- publishing date
- 2008
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Sensors
- volume
- 8
- issue
- 3
- pages
- 1595 - 1612
- publisher
- MDPI AG
- external identifiers
-
- scopus:41549120284
- ISSN
- 1424-8220
- DOI
- 10.3390/s8031595
- language
- English
- LU publication?
- no
- additional info
- Invited Review Article
- id
- ee9d6397-260a-4b6e-a6b2-a3bf6987f57d (old id 3130342)
- date added to LUP
- 2016-04-01 13:57:11
- date last changed
- 2022-04-06 07:56:10
@article{ee9d6397-260a-4b6e-a6b2-a3bf6987f57d, abstract = {{Here, we present the activities within our research group over the last five yearswith cantilevers fabricated in the polymer SU-8. We believe that SU-8 is an interestingpolymer for fabrication of cantilevers for bio/chemical sensing due to its simple processingand low Young’s modulus. We show examples of different integrated read-out methodsand their characterisation. We also show that SU-8 cantilevers have a reduced sensitivity tochanges in the environmental temperature and pH of the buffer solution. Moreover, weshow that the SU-8 cantilever surface can be functionalised directly with receptormolecules for analyte detection, thereby avoiding gold-thiol chemistry.}}, author = {{Nordström, Maria and Keller, Stephan and Lillemose, Michael and Johansson, Alicia and Dohn, Søren and Haefliger, Daniel and Blagoi, Gabriela and Havsteen-Jakobsen, Mogens and Boisen, Anja}}, issn = {{1424-8220}}, language = {{eng}}, number = {{3}}, pages = {{1595--1612}}, publisher = {{MDPI AG}}, series = {{Sensors}}, title = {{SU-8 Cantilever for Bio/chemical Sensing; Fabrication, Characterisation and Development of Novel Read-out Methods}}, url = {{http://dx.doi.org/10.3390/s8031595}}, doi = {{10.3390/s8031595}}, volume = {{8}}, year = {{2008}}, }