A high resolution AMS-injector for the Pelletron in Lund
(2002) In Pramana 59(6). p.1061-1073- Abstract
- A high resolution injector system has recently been installed at the Lund 3 MV tandem Pelletron accelerator. The new injector, designed mainly for Al-26 ions, will increase the experimental potential of the Lund AMS facility considerably. High quality energy- and mass-resolution is obtained by using a 90degrees spherical electrostatic analyzer followed by a 90degrees magnetic analyzer. The injector is equipped with a high intensity sputtering source with a spherical ionizer. A new analytical technique for acceptance calculations as well as PC-based computational methods have been used in the design of the ion optical system of the new injector. Compared to our old injector system which has a magnetic analyzer with a bending angle of only... (More)
- A high resolution injector system has recently been installed at the Lund 3 MV tandem Pelletron accelerator. The new injector, designed mainly for Al-26 ions, will increase the experimental potential of the Lund AMS facility considerably. High quality energy- and mass-resolution is obtained by using a 90degrees spherical electrostatic analyzer followed by a 90degrees magnetic analyzer. The injector is equipped with a high intensity sputtering source with a spherical ionizer. A new analytical technique for acceptance calculations as well as PC-based computational methods have been used in the design of the ion optical system of the new injector. Compared to our old injector system which has a magnetic analyzer with a bending angle of only 15degrees, the new system has a more than ten times better resolution. The beam optics of the new system is also better designed to match the accelerator acceptance. In this way the ion transmission from the ion source to the detector, for different ions of interest in our AMS programme, has been increased. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/320560
- author
- Hellborg, Ragnar LU ; Bazhal, S ; Faarinen, Mikko LU ; Hakansson, K ; Magnusson, Carl-Erik LU ; Persson, Per LU ; Skog, Göran LU and Stenström, Kristina LU
- organization
- publishing date
- 2002
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- AMS, injector, ion optical system, electrostatic accelerator, Pelletron, accelerator mass spectrometry
- in
- Pramana
- volume
- 59
- issue
- 6
- pages
- 1061 - 1073
- publisher
- Springer
- external identifiers
-
- wos:000179994800020
- scopus:0036917302
- ISSN
- 0973-7111
- language
- English
- LU publication?
- yes
- additional info
- The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Nuclear Physics (Faculty of Science) (011013004), Quaternary Sciences (011006008), Physics, science (011013100)
- id
- 5f0d20fb-e94e-456f-88d5-87fa23a2b501 (old id 320560)
- alternative location
- http://www.ias.ac.in/pramana/v59/p1061/fulltext.pdf
- date added to LUP
- 2016-04-01 11:47:44
- date last changed
- 2022-02-25 21:29:48
@article{5f0d20fb-e94e-456f-88d5-87fa23a2b501, abstract = {{A high resolution injector system has recently been installed at the Lund 3 MV tandem Pelletron accelerator. The new injector, designed mainly for Al-26 ions, will increase the experimental potential of the Lund AMS facility considerably. High quality energy- and mass-resolution is obtained by using a 90degrees spherical electrostatic analyzer followed by a 90degrees magnetic analyzer. The injector is equipped with a high intensity sputtering source with a spherical ionizer. A new analytical technique for acceptance calculations as well as PC-based computational methods have been used in the design of the ion optical system of the new injector. Compared to our old injector system which has a magnetic analyzer with a bending angle of only 15degrees, the new system has a more than ten times better resolution. The beam optics of the new system is also better designed to match the accelerator acceptance. In this way the ion transmission from the ion source to the detector, for different ions of interest in our AMS programme, has been increased.}}, author = {{Hellborg, Ragnar and Bazhal, S and Faarinen, Mikko and Hakansson, K and Magnusson, Carl-Erik and Persson, Per and Skog, Göran and Stenström, Kristina}}, issn = {{0973-7111}}, keywords = {{AMS; injector; ion optical system; electrostatic accelerator; Pelletron; accelerator mass spectrometry}}, language = {{eng}}, number = {{6}}, pages = {{1061--1073}}, publisher = {{Springer}}, series = {{Pramana}}, title = {{A high resolution AMS-injector for the Pelletron in Lund}}, url = {{http://www.ias.ac.in/pramana/v59/p1061/fulltext.pdf}}, volume = {{59}}, year = {{2002}}, }