On-line automated sample preparation for liquid chromatography using parallel supported liquid membrane extraction and microporous membrane liquid-liquid extraction
(2002) In Journal of Chromatography A 975(1). p.211-217- Abstract
- An automated system was developed for analysis of non-polar and polar ionisable compounds at trace levels in natural water. Sample work-up was performed in a flow system using two parallel membrane extraction units. This system was connected on-line to a reversed-phase HPLC system for final determination. One of the membrane units was used for supported liquid membrane (SLM) extraction, which is suitable for ionisable or permanently charged compounds. The other unit was used for microporous membrane liquid-liquid extraction (MMLLE) suitable for uncharged compounds. The fungicide thiophanate methyl and its polar metabolites carbendazim and 2-aminobenzimidazole were used as model compounds. The whole system was controlled by means of four... (More)
- An automated system was developed for analysis of non-polar and polar ionisable compounds at trace levels in natural water. Sample work-up was performed in a flow system using two parallel membrane extraction units. This system was connected on-line to a reversed-phase HPLC system for final determination. One of the membrane units was used for supported liquid membrane (SLM) extraction, which is suitable for ionisable or permanently charged compounds. The other unit was used for microporous membrane liquid-liquid extraction (MMLLE) suitable for uncharged compounds. The fungicide thiophanate methyl and its polar metabolites carbendazim and 2-aminobenzimidazole were used as model compounds. The whole system was controlled by means of four syringe pumps. While extracting one part of the sample using the SLM technique, the extract from the MMLLE extraction was analysed and vice versa. This gave a total analysis time of 63 min for each sample resulting in a sample throughput of 22 samples per 24 h. (C) 2002 Elsevier Science B.V. All rights reserved. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/324483
- author
- Sandahl, Margareta LU ; Mathiasson, Lennart LU and Jönsson, Jan Åke LU
- organization
- publishing date
- 2002
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- Fungicides, Microporous membranes, Sample preparation, Supported liquid membranes, carbendazim, fungicide, imidazole derivative, ion, analytic method, article, automation, experimental model, liquid liquid extraction, microporous liquid liquid extraction, online system, priority journal, reversed phase high performance liquid chromatography, sample, supported liquid membrane extraction, syringe, time
- in
- Journal of Chromatography A
- volume
- 975
- issue
- 1
- pages
- 7 pages
- publisher
- Elsevier
- external identifiers
-
- wos:000178947600017
- pmid:12458761
- scopus:0037174698
- ISSN
- 0021-9673
- DOI
- 10.1016/S0021-9673(02)00880-4
- language
- English
- LU publication?
- yes
- additional info
- The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Analytical Chemistry (S/LTH) (011001004)
- id
- a330a5eb-8f97-4ac1-ba2e-b110c79f26e5 (old id 324483)
- date added to LUP
- 2016-04-01 15:49:02
- date last changed
- 2022-02-27 08:57:00
@article{a330a5eb-8f97-4ac1-ba2e-b110c79f26e5, abstract = {{An automated system was developed for analysis of non-polar and polar ionisable compounds at trace levels in natural water. Sample work-up was performed in a flow system using two parallel membrane extraction units. This system was connected on-line to a reversed-phase HPLC system for final determination. One of the membrane units was used for supported liquid membrane (SLM) extraction, which is suitable for ionisable or permanently charged compounds. The other unit was used for microporous membrane liquid-liquid extraction (MMLLE) suitable for uncharged compounds. The fungicide thiophanate methyl and its polar metabolites carbendazim and 2-aminobenzimidazole were used as model compounds. The whole system was controlled by means of four syringe pumps. While extracting one part of the sample using the SLM technique, the extract from the MMLLE extraction was analysed and vice versa. This gave a total analysis time of 63 min for each sample resulting in a sample throughput of 22 samples per 24 h. (C) 2002 Elsevier Science B.V. All rights reserved.}}, author = {{Sandahl, Margareta and Mathiasson, Lennart and Jönsson, Jan Åke}}, issn = {{0021-9673}}, keywords = {{Fungicides; Microporous membranes; Sample preparation; Supported liquid membranes; carbendazim; fungicide; imidazole derivative; ion; analytic method; article; automation; experimental model; liquid liquid extraction; microporous liquid liquid extraction; online system; priority journal; reversed phase high performance liquid chromatography; sample; supported liquid membrane extraction; syringe; time}}, language = {{eng}}, number = {{1}}, pages = {{211--217}}, publisher = {{Elsevier}}, series = {{Journal of Chromatography A}}, title = {{On-line automated sample preparation for liquid chromatography using parallel supported liquid membrane extraction and microporous membrane liquid-liquid extraction}}, url = {{http://dx.doi.org/10.1016/S0021-9673(02)00880-4}}, doi = {{10.1016/S0021-9673(02)00880-4}}, volume = {{975}}, year = {{2002}}, }