Quantitative three-dimensional imaging of soot volume fraction in turbulent non-premixed flames
(2002) In Experiments in Fluids 33(2). p.265-269- Abstract
- A three-dimensional (3-D) imaging system for studies of reactive and non-reactive flows is described. It can be used to reveal the topology of turbulent structures and to extract 3-D quantities, such as concentration gradients. Measurements are performed using a high repetition rate laser and detector system in combination with a scanning mirror. In this study, the system is used for laser-induced incandescence measurements to obtain quantitative 3-D soot volume fraction distributions in both laminar and turbulent non-premixed flames. From the acquired data, iso-concentration surfaces are visualised and concentration gradients calculated.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/329484
- author
- Hult, Johan LU ; Omrane, Alaa LU ; Nygren, Jenny LU ; Kaminski, Clemens LU ; Axelsson, Boman LU ; Collin, Robert LU ; Bengtsson, Per-Erik LU and Aldén, Marcus LU
- organization
- publishing date
- 2002
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Experiments in Fluids
- volume
- 33
- issue
- 2
- pages
- 265 - 269
- publisher
- Springer
- external identifiers
-
- wos:000177729300006
- scopus:0036687468
- ISSN
- 1432-1114
- DOI
- 10.1007/s00348-002-0410-2
- language
- English
- LU publication?
- yes
- id
- 33f18166-2186-4ad4-a5c0-106a104b7f92 (old id 329484)
- date added to LUP
- 2016-04-01 11:53:05
- date last changed
- 2022-04-13 02:46:34
@article{33f18166-2186-4ad4-a5c0-106a104b7f92, abstract = {{A three-dimensional (3-D) imaging system for studies of reactive and non-reactive flows is described. It can be used to reveal the topology of turbulent structures and to extract 3-D quantities, such as concentration gradients. Measurements are performed using a high repetition rate laser and detector system in combination with a scanning mirror. In this study, the system is used for laser-induced incandescence measurements to obtain quantitative 3-D soot volume fraction distributions in both laminar and turbulent non-premixed flames. From the acquired data, iso-concentration surfaces are visualised and concentration gradients calculated.}}, author = {{Hult, Johan and Omrane, Alaa and Nygren, Jenny and Kaminski, Clemens and Axelsson, Boman and Collin, Robert and Bengtsson, Per-Erik and Aldén, Marcus}}, issn = {{1432-1114}}, language = {{eng}}, number = {{2}}, pages = {{265--269}}, publisher = {{Springer}}, series = {{Experiments in Fluids}}, title = {{Quantitative three-dimensional imaging of soot volume fraction in turbulent non-premixed flames}}, url = {{http://dx.doi.org/10.1007/s00348-002-0410-2}}, doi = {{10.1007/s00348-002-0410-2}}, volume = {{33}}, year = {{2002}}, }