Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

A study of long-term effects on plasmid-containing Escherichia coli in carbon-limited chemostat using 2D-fluorescence spectrofluorimetry

Johansson, Louise LU and Lidén, Gunnar LU (2006) In Biotechnology Progress 22(4). p.1132-1139
Abstract
Strain stability of plasmid-containing recombinant organisms is clearly important for industrial applications. Stability is normally assessed by methods such as selective colony forming units or by simply measuring the recombinant product. These methods are typically performed off-line, are time-consuming, and do not give detailed information on the changes in the metabolism. In the current work, long-term stability of a plasmid-containing strain of Escherichia coli (W3110.shik1) capable of shikimic acid overproduction was studied by means of a 2D-fluorescence sensor (BioView) able to emit and detect light in ranges of 260-560 nm and 300600 nm, respectively. Long-term carbon-limited chemostat experiments were made under both selective... (More)
Strain stability of plasmid-containing recombinant organisms is clearly important for industrial applications. Stability is normally assessed by methods such as selective colony forming units or by simply measuring the recombinant product. These methods are typically performed off-line, are time-consuming, and do not give detailed information on the changes in the metabolism. In the current work, long-term stability of a plasmid-containing strain of Escherichia coli (W3110.shik1) capable of shikimic acid overproduction was studied by means of a 2D-fluorescence sensor (BioView) able to emit and detect light in ranges of 260-560 nm and 300600 nm, respectively. Long-term carbon-limited chemostat experiments were made under both selective (tetracycline-containing medium) and nonselective conditions. It is shown that the fluorescence spectra provide information about metabolic changes at an earlier stage, thereby giving a noninvasive method for monitoring of strain stability. Further, the fluorescence measurements showed that (i) the metabolic changes in the strain W3110.shik1 with time were qualitatively different in selective and nonselective environment, (ii) plasmid recombination resulted primarily in increased biomass yield, and (iii) a change in metabolism probably involving FAD/FMN and pyridoxal-5-P occurred in all experiments. It was concluded that the strain was not stable in any growth condition for more than about 25 growth generations and even less if plasmid recombination took place. (Less)
Please use this url to cite or link to this publication:
author
and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Biotechnology Progress
volume
22
issue
4
pages
1132 - 1139
publisher
The American Chemical Society (ACS)
external identifiers
  • wos:000239493200028
  • scopus:33747153049
ISSN
1520-6033
DOI
10.1021/bp060061m
language
English
LU publication?
yes
id
252e0609-07f3-407d-8c67-7c62efd15f15 (old id 399224)
date added to LUP
2016-04-01 16:41:21
date last changed
2023-09-04 23:23:35
@article{252e0609-07f3-407d-8c67-7c62efd15f15,
  abstract     = {{Strain stability of plasmid-containing recombinant organisms is clearly important for industrial applications. Stability is normally assessed by methods such as selective colony forming units or by simply measuring the recombinant product. These methods are typically performed off-line, are time-consuming, and do not give detailed information on the changes in the metabolism. In the current work, long-term stability of a plasmid-containing strain of Escherichia coli (W3110.shik1) capable of shikimic acid overproduction was studied by means of a 2D-fluorescence sensor (BioView) able to emit and detect light in ranges of 260-560 nm and 300600 nm, respectively. Long-term carbon-limited chemostat experiments were made under both selective (tetracycline-containing medium) and nonselective conditions. It is shown that the fluorescence spectra provide information about metabolic changes at an earlier stage, thereby giving a noninvasive method for monitoring of strain stability. Further, the fluorescence measurements showed that (i) the metabolic changes in the strain W3110.shik1 with time were qualitatively different in selective and nonselective environment, (ii) plasmid recombination resulted primarily in increased biomass yield, and (iii) a change in metabolism probably involving FAD/FMN and pyridoxal-5-P occurred in all experiments. It was concluded that the strain was not stable in any growth condition for more than about 25 growth generations and even less if plasmid recombination took place.}},
  author       = {{Johansson, Louise and Lidén, Gunnar}},
  issn         = {{1520-6033}},
  language     = {{eng}},
  number       = {{4}},
  pages        = {{1132--1139}},
  publisher    = {{The American Chemical Society (ACS)}},
  series       = {{Biotechnology Progress}},
  title        = {{A study of long-term effects on plasmid-containing Escherichia coli in carbon-limited chemostat using 2D-fluorescence spectrofluorimetry}},
  url          = {{http://dx.doi.org/10.1021/bp060061m}},
  doi          = {{10.1021/bp060061m}},
  volume       = {{22}},
  year         = {{2006}},
}