Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Methods for handwear, footwear and headgear evaluation

Kuklane, Kalev LU ; Nilsson, Håkan ; Holmér, Ingvar LU and Liu, Xiaoxiong (1997) A European seminar on Thermal Manikin Testing In Arbetslivsrapport p.23-29
Abstract
1. General principles (Qm=Pm/Am; Itr=(Tm-Ta)/Qm; possible to make measurements at constant surface temperature or heatloss, in all examples surface temperature was kept constant).

2. Handwear

2.1 Ten (10) zones; standard (EN 511)

2.2 Setup

2.3 Example from results

3. Headgear

3.1 Six (6) zones

3.2 Setup & conditions (Ta, wetting, wind & humidity)

3.3 Example from results

4. Footwear

4.1 Eight (8) zones & 3 sweat glands, size 41.

4.2 Setup & conditions (standing on a copper-zinc alloy plate in a climatic chamber).

4.3 Example from results (total values for zones up to ankle).
Please use this url to cite or link to this publication:
author
; ; and
organization
publishing date
type
Chapter in Book/Report/Conference proceeding
publication status
published
subject
host publication
Proceedings of a European seminar on thermal manikin testing at the National Institute for Working Life, Wednesday, February 12, 1997
series title
Arbetslivsrapport
editor
Nilsson, Håkan and Holmér, Ingvar
issue
1997:9
pages
7 pages
publisher
Department of Ergonomics, Arbetslivsinstitutet, Solna, Sweden
conference name
A European seminar on Thermal Manikin Testing
conference location
Arbetslivsinstitutet, Solna, Sweden
conference dates
1997-02-12
ISSN
1401-2928
language
English
LU publication?
no
id
3ee4e3f0-b6b6-4eb8-8b99-2da327dcd74b (old id 635720)
date added to LUP
2016-04-01 16:21:32
date last changed
2018-11-21 20:40:46
@inproceedings{3ee4e3f0-b6b6-4eb8-8b99-2da327dcd74b,
  abstract     = {{1. General principles (Qm=Pm/Am; Itr=(Tm-Ta)/Qm; possible to make measurements at constant 	surface temperature or heatloss, in all examples surface temperature was kept constant).<br/><br>
2. Handwear<br/><br>
2.1 Ten (10) zones; standard (EN 511)<br/><br>
2.2 Setup<br/><br>
2.3 Example from results<br/><br>
3. Headgear<br/><br>
3.1 Six (6) zones<br/><br>
3.2 Setup &amp; conditions (Ta, wetting, wind &amp; humidity)<br/><br>
3.3 Example from results<br/><br>
4. Footwear<br/><br>
4.1 Eight (8) zones &amp; 3 sweat glands, size 41.<br/><br>
4.2 Setup &amp; conditions (standing on a copper-zinc alloy plate in a climatic chamber).<br/><br>
4.3 Example from results (total values for zones up to ankle).}},
  author       = {{Kuklane, Kalev and Nilsson, Håkan and Holmér, Ingvar and Liu, Xiaoxiong}},
  booktitle    = {{Proceedings of a European seminar on thermal manikin testing at the National Institute for Working Life, Wednesday, February 12, 1997}},
  editor       = {{Nilsson, Håkan and Holmér, Ingvar}},
  issn         = {{1401-2928}},
  language     = {{eng}},
  number       = {{1997:9}},
  pages        = {{23--29}},
  publisher    = {{Department of Ergonomics, Arbetslivsinstitutet, Solna, Sweden}},
  series       = {{Arbetslivsrapport}},
  title        = {{Methods for handwear, footwear and headgear evaluation}},
  year         = {{1997}},
}