Monte-Carlo simulation of the charged particle detector used in the NORDBALL gamma-ray spectrometer

Ashrafi, S ; Lipoglavsek, M ; Likar, A ; Vidmar, T ; Cederkäll, Joakim LU ; Fahlander, C ; Grawe, H ; Johnson, A ; Mitarai, S and Norlin, LO , et al. (2001) In Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment 458(3). p.690-697
Abstract
The NORDBALL silicon detector array for detecting light charged particles emitted in fusion evaporation reactions was simulated with the Monte-Carlo method. The data from the reaction of 261 MeV Ni-58 ions with Cr-50 nuclei in a 4.8 mg/cm(2) thick target was used to adjust the simulation parameters. Relative population of residual nuclei in the reaction was determined, by comparing the intensities of gamma -rays. (C) 2001 Elsevier Science B.V. All rights reserved.
Please use this url to cite or link to this publication:
author
; ; ; ; ; ; ; ; and , et al. (More)
; ; ; ; ; ; ; ; ; ; ; ; ; ; and (Less)
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Monte-Carlo calculation, NORDBALL, in-beam spectroscopy
in
Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment
volume
458
issue
3
pages
690 - 697
publisher
Elsevier
external identifiers
  • wos:000167040900009
  • scopus:0035252621
ISSN
0167-5087
DOI
10.1016/S0168-9002(00)00894-9
language
English
LU publication?
no
id
8660060a-3889-430d-bbdb-fc8bc5e27d28 (old id 4281850)
date added to LUP
2016-04-01 17:10:38
date last changed
2022-01-29 00:55:26
@article{8660060a-3889-430d-bbdb-fc8bc5e27d28,
  abstract     = {{The NORDBALL silicon detector array for detecting light charged particles emitted in fusion evaporation reactions was simulated with the Monte-Carlo method. The data from the reaction of 261 MeV Ni-58 ions with Cr-50 nuclei in a 4.8 mg/cm(2) thick target was used to adjust the simulation parameters. Relative population of residual nuclei in the reaction was determined, by comparing the intensities of gamma -rays. (C) 2001 Elsevier Science B.V. All rights reserved.}},
  author       = {{Ashrafi, S and Lipoglavsek, M and Likar, A and Vidmar, T and Cederkäll, Joakim and Fahlander, C and Grawe, H and Johnson, A and Mitarai, S and Norlin, LO and Nyberg, J and Palacz, M and Persson, J and Seweryniak, D and Shizuma, T and Sletten, G}},
  issn         = {{0167-5087}},
  keywords     = {{Monte-Carlo calculation; NORDBALL; in-beam spectroscopy}},
  language     = {{eng}},
  number       = {{3}},
  pages        = {{690--697}},
  publisher    = {{Elsevier}},
  series       = {{Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment}},
  title        = {{Monte-Carlo simulation of the charged particle detector used in the NORDBALL gamma-ray spectrometer}},
  url          = {{http://dx.doi.org/10.1016/S0168-9002(00)00894-9}},
  doi          = {{10.1016/S0168-9002(00)00894-9}},
  volume       = {{458}},
  year         = {{2001}},
}