Advanced

Monte-Carlo simulation of the charged particle detector used in the NORDBALL gamma-ray spectrometer

Ashrafi, S; Lipoglavsek, M; Likar, A; Vidmar, T; Cederkäll, Joakim LU ; Fahlander, C; Grawe, H; Johnson, A; Mitarai, S and Norlin, LO, et al. (2001) In Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment 458(3). p.690-697
Abstract
The NORDBALL silicon detector array for detecting light charged particles emitted in fusion evaporation reactions was simulated with the Monte-Carlo method. The data from the reaction of 261 MeV Ni-58 ions with Cr-50 nuclei in a 4.8 mg/cm(2) thick target was used to adjust the simulation parameters. Relative population of residual nuclei in the reaction was determined, by comparing the intensities of gamma -rays. (C) 2001 Elsevier Science B.V. All rights reserved.
Please use this url to cite or link to this publication:
author
, et al. (More)
(Less)
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Monte-Carlo calculation, NORDBALL, in-beam spectroscopy
in
Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment
volume
458
issue
3
pages
690 - 697
publisher
Elsevier
external identifiers
  • wos:000167040900009
  • scopus:0035252621
ISSN
0167-5087
DOI
10.1016/S0168-9002(00)00894-9
language
English
LU publication?
no
id
8660060a-3889-430d-bbdb-fc8bc5e27d28 (old id 4281850)
date added to LUP
2014-02-03 10:39:53
date last changed
2018-10-03 11:06:03
@article{8660060a-3889-430d-bbdb-fc8bc5e27d28,
  abstract     = {The NORDBALL silicon detector array for detecting light charged particles emitted in fusion evaporation reactions was simulated with the Monte-Carlo method. The data from the reaction of 261 MeV Ni-58 ions with Cr-50 nuclei in a 4.8 mg/cm(2) thick target was used to adjust the simulation parameters. Relative population of residual nuclei in the reaction was determined, by comparing the intensities of gamma -rays. (C) 2001 Elsevier Science B.V. All rights reserved.},
  author       = {Ashrafi, S and Lipoglavsek, M and Likar, A and Vidmar, T and Cederkäll, Joakim and Fahlander, C and Grawe, H and Johnson, A and Mitarai, S and Norlin, LO and Nyberg, J and Palacz, M and Persson, J and Seweryniak, D and Shizuma, T and Sletten, G},
  issn         = {0167-5087},
  keyword      = {Monte-Carlo calculation,NORDBALL,in-beam spectroscopy},
  language     = {eng},
  number       = {3},
  pages        = {690--697},
  publisher    = {Elsevier},
  series       = {Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment},
  title        = {Monte-Carlo simulation of the charged particle detector used in the NORDBALL gamma-ray spectrometer},
  url          = {http://dx.doi.org/10.1016/S0168-9002(00)00894-9},
  volume       = {458},
  year         = {2001},
}