Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Improved modeling of heat transfer in dropwise condensation

Wang, Jinshi LU ; Ma, Ziqiang ; Li, Gen ; Sundén, Bengt LU and Yan, Junjie (2020) In International Journal of Heat and Mass Transfer 155.
Abstract

Dropwise condensation has drawn significant attention due to its efficient heat transfer performance compared to filmwise condensation. In this paper, typical experimental data for dropwise condensation on smooth hydrophobic surfaces were collected as well as the typical available heat transfer models. The comparisons between the prediction results and the experimental data indicated that the existing models were not generally applicable to various conditions. A new model for a vertical smooth surface was developed to predict the heat transfer characteristics of dropwise condensation. The new model was based on the nucleation condensation mechanism, and the total heat transfer on the surface includes the heat through all the droplets... (More)

Dropwise condensation has drawn significant attention due to its efficient heat transfer performance compared to filmwise condensation. In this paper, typical experimental data for dropwise condensation on smooth hydrophobic surfaces were collected as well as the typical available heat transfer models. The comparisons between the prediction results and the experimental data indicated that the existing models were not generally applicable to various conditions. A new model for a vertical smooth surface was developed to predict the heat transfer characteristics of dropwise condensation. The new model was based on the nucleation condensation mechanism, and the total heat transfer on the surface includes the heat through all the droplets and the heat through the surface between the droplets. For the latent heat through the droplets the effect of the contact angle was taken into consideration on the basis of the nucleation condensation mechanism. The surface area between the droplets on the surface was thought to be the bare surface, and sensible heat transferred on the bare surface and the droplets surface was viewed as forced convection heat transfer. The calculation results from the model show that, although the heat transferred by forced convection is greatly dependent on the experimental parameters, it is three orders of magnitude smaller than the latent heat through the droplets. Comparisons show that the present model has better prediction precision, with an error range of -35–20% for 87.39% of the data and an error range of -35–25% for 90.37% of the data. The findings obtained from the model suggest that the heat transfer rate and the critical nucleation radius for a single droplet and the droplet size distribution are remarkably affected by the contact angle. In fact, a smaller contact angle enhances the condensation heat transfer and increases the nucleation density. In addition, the thickness of the promoter layer weakens the condensation heat transfer and decreases the nucleation density.

(Less)
Please use this url to cite or link to this publication:
author
; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Droplet, Dropwise condensation, Heat transfer, Model
in
International Journal of Heat and Mass Transfer
volume
155
article number
119719
publisher
Pergamon Press Ltd.
external identifiers
  • scopus:85084354642
ISSN
0017-9310
DOI
10.1016/j.ijheatmasstransfer.2020.119719
language
English
LU publication?
yes
id
434d6440-8c25-410f-861c-d9032ecd251f
date added to LUP
2020-06-01 14:38:14
date last changed
2023-11-20 05:18:31
@article{434d6440-8c25-410f-861c-d9032ecd251f,
  abstract     = {{<p>Dropwise condensation has drawn significant attention due to its efficient heat transfer performance compared to filmwise condensation. In this paper, typical experimental data for dropwise condensation on smooth hydrophobic surfaces were collected as well as the typical available heat transfer models. The comparisons between the prediction results and the experimental data indicated that the existing models were not generally applicable to various conditions. A new model for a vertical smooth surface was developed to predict the heat transfer characteristics of dropwise condensation. The new model was based on the nucleation condensation mechanism, and the total heat transfer on the surface includes the heat through all the droplets and the heat through the surface between the droplets. For the latent heat through the droplets the effect of the contact angle was taken into consideration on the basis of the nucleation condensation mechanism. The surface area between the droplets on the surface was thought to be the bare surface, and sensible heat transferred on the bare surface and the droplets surface was viewed as forced convection heat transfer. The calculation results from the model show that, although the heat transferred by forced convection is greatly dependent on the experimental parameters, it is three orders of magnitude smaller than the latent heat through the droplets. Comparisons show that the present model has better prediction precision, with an error range of -35–20% for 87.39% of the data and an error range of -35–25% for 90.37% of the data. The findings obtained from the model suggest that the heat transfer rate and the critical nucleation radius for a single droplet and the droplet size distribution are remarkably affected by the contact angle. In fact, a smaller contact angle enhances the condensation heat transfer and increases the nucleation density. In addition, the thickness of the promoter layer weakens the condensation heat transfer and decreases the nucleation density.</p>}},
  author       = {{Wang, Jinshi and Ma, Ziqiang and Li, Gen and Sundén, Bengt and Yan, Junjie}},
  issn         = {{0017-9310}},
  keywords     = {{Droplet; Dropwise condensation; Heat transfer; Model}},
  language     = {{eng}},
  publisher    = {{Pergamon Press Ltd.}},
  series       = {{International Journal of Heat and Mass Transfer}},
  title        = {{Improved modeling of heat transfer in dropwise condensation}},
  url          = {{http://dx.doi.org/10.1016/j.ijheatmasstransfer.2020.119719}},
  doi          = {{10.1016/j.ijheatmasstransfer.2020.119719}},
  volume       = {{155}},
  year         = {{2020}},
}