Investigating the effect of adding comparisons with prior mammograms to standalone digital breast tomosynthesis screening

Timberg, Pontus LU ; Hellgren, Gustav LU orcid ; Dustler, Magnus LU orcid and Tingberg, Anders LU orcid (2025) In Journal of Medical Imaging 12.
Abstract

Purpose: The purpose is to retrospectively investigate how the addition of prior and concurrent mammograms affects wide-angle digital breast tomosynthesis (DBT) screening false-positive recall rates, malignancy scoring, and recall agreement. Approach: A total of 200 cases were selected from the Malmö Breast Tomosynthesis Screening Trial. They consist of 150 recalled cases [30 true positives (TPs), 120 false positives (FPs), and 50 healthy, non-recalled true-negative (TN) cases]. The positive cases were categorized based on being recalled by either DBT, digital mammography (DM), or both. Each case had DBT, synthetic mammography (SM), and DM (prior screening round) images. Five radiologists participated in a reading study where detection,... (More)

Purpose: The purpose is to retrospectively investigate how the addition of prior and concurrent mammograms affects wide-angle digital breast tomosynthesis (DBT) screening false-positive recall rates, malignancy scoring, and recall agreement. Approach: A total of 200 cases were selected from the Malmö Breast Tomosynthesis Screening Trial. They consist of 150 recalled cases [30 true positives (TPs), 120 false positives (FPs), and 50 healthy, non-recalled true-negative (TN) cases]. The positive cases were categorized based on being recalled by either DBT, digital mammography (DM), or both. Each case had DBT, synthetic mammography (SM), and DM (prior screening round) images. Five radiologists participated in a reading study where detection, risk of malignancy, and recall were assessed. They read each case twice, once using only DBT and once using DBT together with SM and DM priors. Results: The results showed a significant reduction in recall rates for all FP categories, as well as for the TN cases, when adding SM and prior DM to DBT. This resulted also in a significant increase in recall agreement for these categories, with more of the negative cases being recalled by few or no readers. These categories were overall rated as appearing more malignant in the DBT reading arm. For the TP categories, there was a significant decrease in recalls for DM-recalled cancers (p ¼ 0.047), but no significant difference for DBT-recalled cancers (p ¼ 0.063), or DBT/DM-recalled cancers (p ¼ 0.208). Conclusions: Similar to the documented effect of priors in DM screening, we suggest that added two-dimensional priors improve the specificity of DBT screening but may reduce the sensitivity.

(Less)
Please use this url to cite or link to this publication:
author
; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
digital breast tomosynthesis, digital mammography, synthetic mammography
in
Journal of Medical Imaging
volume
12
article number
S22003
publisher
SPIE
external identifiers
  • pmid:40134462
  • scopus:105015465390
ISSN
2329-4302
DOI
10.1117/1.JMI.12.S2.S22003
language
English
LU publication?
yes
id
46f964e8-1f16-4092-9039-75803b38776c
date added to LUP
2025-10-03 13:27:17
date last changed
2025-10-04 03:08:06
@article{46f964e8-1f16-4092-9039-75803b38776c,
  abstract     = {{<p>Purpose: The purpose is to retrospectively investigate how the addition of prior and concurrent mammograms affects wide-angle digital breast tomosynthesis (DBT) screening false-positive recall rates, malignancy scoring, and recall agreement. Approach: A total of 200 cases were selected from the Malmö Breast Tomosynthesis Screening Trial. They consist of 150 recalled cases [30 true positives (TPs), 120 false positives (FPs), and 50 healthy, non-recalled true-negative (TN) cases]. The positive cases were categorized based on being recalled by either DBT, digital mammography (DM), or both. Each case had DBT, synthetic mammography (SM), and DM (prior screening round) images. Five radiologists participated in a reading study where detection, risk of malignancy, and recall were assessed. They read each case twice, once using only DBT and once using DBT together with SM and DM priors. Results: The results showed a significant reduction in recall rates for all FP categories, as well as for the TN cases, when adding SM and prior DM to DBT. This resulted also in a significant increase in recall agreement for these categories, with more of the negative cases being recalled by few or no readers. These categories were overall rated as appearing more malignant in the DBT reading arm. For the TP categories, there was a significant decrease in recalls for DM-recalled cancers (p ¼ 0.047), but no significant difference for DBT-recalled cancers (p ¼ 0.063), or DBT/DM-recalled cancers (p ¼ 0.208). Conclusions: Similar to the documented effect of priors in DM screening, we suggest that added two-dimensional priors improve the specificity of DBT screening but may reduce the sensitivity.</p>}},
  author       = {{Timberg, Pontus and Hellgren, Gustav and Dustler, Magnus and Tingberg, Anders}},
  issn         = {{2329-4302}},
  keywords     = {{digital breast tomosynthesis; digital mammography; synthetic mammography}},
  language     = {{eng}},
  publisher    = {{SPIE}},
  series       = {{Journal of Medical Imaging}},
  title        = {{Investigating the effect of adding comparisons with prior mammograms to standalone digital breast tomosynthesis screening}},
  url          = {{http://dx.doi.org/10.1117/1.JMI.12.S2.S22003}},
  doi          = {{10.1117/1.JMI.12.S2.S22003}},
  volume       = {{12}},
  year         = {{2025}},
}