The tagged photon facility at the MAX IV Laboratory
(2014) International Nuclear Physics Conference (INPC) 66. p.11035-11035- Abstract
- The upgraded tagged photon facility at the MAX IV Laboratory is presented. The pulsed electron beam from a linac system is stretched in the MAX I ring and the electron beam hits a thin aluminium foil in which bremsstrahlung is produced. One of two available magnetic spectrometers is used to determine the energy of the post-bremsstrahlung electrons. The tagged photon ranges from 10 to 180 MeV with an energy resolution of about 300 keV. Rates as high as 4x10(6) photons s(-1) MeV-1 have been used. The experimental area and facilities are described as well as examples of ongoing experiments.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/4803715
- author
- Schröder, Bent LU
- organization
- publishing date
- 2014
- type
- Chapter in Book/Report/Conference proceeding
- publication status
- published
- subject
- host publication
- INPC 2013 - International Nuclear Physics Conference, Vol. 2
- volume
- 66
- pages
- 11035 - 11035
- publisher
- EDP Sciences
- conference name
- International Nuclear Physics Conference (INPC)
- conference dates
- 2013-06-02 - 2013-06-07
- external identifiers
-
- wos:000342463600189
- scopus:84898718329
- ISSN
- 2100-014X
- 2101-6275
- DOI
- 10.1051/epjconf/20146611035
- language
- English
- LU publication?
- yes
- id
- 344926d8-10a4-4989-bfa5-ab5059a6bd08 (old id 4803715)
- date added to LUP
- 2016-04-01 10:18:06
- date last changed
- 2025-01-14 11:17:08
@inproceedings{344926d8-10a4-4989-bfa5-ab5059a6bd08, abstract = {{The upgraded tagged photon facility at the MAX IV Laboratory is presented. The pulsed electron beam from a linac system is stretched in the MAX I ring and the electron beam hits a thin aluminium foil in which bremsstrahlung is produced. One of two available magnetic spectrometers is used to determine the energy of the post-bremsstrahlung electrons. The tagged photon ranges from 10 to 180 MeV with an energy resolution of about 300 keV. Rates as high as 4x10(6) photons s(-1) MeV-1 have been used. The experimental area and facilities are described as well as examples of ongoing experiments.}}, author = {{Schröder, Bent}}, booktitle = {{INPC 2013 - International Nuclear Physics Conference, Vol. 2}}, issn = {{2100-014X}}, language = {{eng}}, pages = {{11035--11035}}, publisher = {{EDP Sciences}}, title = {{The tagged photon facility at the MAX IV Laboratory}}, url = {{http://dx.doi.org/10.1051/epjconf/20146611035}}, doi = {{10.1051/epjconf/20146611035}}, volume = {{66}}, year = {{2014}}, }