The charge state distribution of Be, C, Cl and Al ions at the Lund Pelletron accelerator with the recently modified terminal pumping in use
(2004) In Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment 521(2-3). p.299-305- Abstract
- Some years ago terminal pumping for the gas stripper system at the 3 MV Lund Tandem Pelletron accelerator was installed and charge state distribution measurements using the new installation were reported. Since then, new modifications of the mechanical design of the stripper system have been made. The results of pressure profile measurements as well as the results of charge state distribution measurements in a N-2 and Ar gas stripper at different, new geometrical modifications of the stripper system using C, Be, Al and Cl ion beams are reported. A comparison between pressure profiles obtained for different geometries shows a clear improvement of the vacuum conditions outside the stripper housing for the smallest conductance pipes between... (More)
- Some years ago terminal pumping for the gas stripper system at the 3 MV Lund Tandem Pelletron accelerator was installed and charge state distribution measurements using the new installation were reported. Since then, new modifications of the mechanical design of the stripper system have been made. The results of pressure profile measurements as well as the results of charge state distribution measurements in a N-2 and Ar gas stripper at different, new geometrical modifications of the stripper system using C, Be, Al and Cl ion beams are reported. A comparison between pressure profiles obtained for different geometries shows a clear improvement of the vacuum conditions outside the stripper housing for the smallest conductance pipes between the stripper system and the accelerator tubes. These improvements are also well reflected in the charge state distribution measurements, as a higher mean charge state is obtained under the same vacuum conditions in the accelerator tubes for the improved stripper system in comparison with the former mechanical design. (C) 2003 Elsevier B.V. All rights reserved. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/282852
- author
- Kiisk, Madis LU ; Hellborg, Ragnar LU ; Persson, Per LU ; Faarinen, Mikko LU ; Skog, Göran LU and Stenström, Kristina LU
- organization
- publishing date
- 2004
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- terminal pumping, pressure profile, tandem accelerator, distribution, charge state
- in
- Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment
- volume
- 521
- issue
- 2-3
- pages
- 299 - 305
- publisher
- Elsevier
- external identifiers
-
- wos:000220607100002
- scopus:1642314098
- ISSN
- 0167-5087
- DOI
- 10.1016/j.nima.2003.11.042
- language
- English
- LU publication?
- yes
- id
- 4aa4487d-98c4-4b4c-b63f-a2b0cce40ff6 (old id 282852)
- date added to LUP
- 2016-04-01 15:56:37
- date last changed
- 2022-01-28 08:11:31
@article{4aa4487d-98c4-4b4c-b63f-a2b0cce40ff6, abstract = {{Some years ago terminal pumping for the gas stripper system at the 3 MV Lund Tandem Pelletron accelerator was installed and charge state distribution measurements using the new installation were reported. Since then, new modifications of the mechanical design of the stripper system have been made. The results of pressure profile measurements as well as the results of charge state distribution measurements in a N-2 and Ar gas stripper at different, new geometrical modifications of the stripper system using C, Be, Al and Cl ion beams are reported. A comparison between pressure profiles obtained for different geometries shows a clear improvement of the vacuum conditions outside the stripper housing for the smallest conductance pipes between the stripper system and the accelerator tubes. These improvements are also well reflected in the charge state distribution measurements, as a higher mean charge state is obtained under the same vacuum conditions in the accelerator tubes for the improved stripper system in comparison with the former mechanical design. (C) 2003 Elsevier B.V. All rights reserved.}}, author = {{Kiisk, Madis and Hellborg, Ragnar and Persson, Per and Faarinen, Mikko and Skog, Göran and Stenström, Kristina}}, issn = {{0167-5087}}, keywords = {{terminal pumping; pressure profile; tandem accelerator; distribution; charge state}}, language = {{eng}}, number = {{2-3}}, pages = {{299--305}}, publisher = {{Elsevier}}, series = {{Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment}}, title = {{The charge state distribution of Be, C, Cl and Al ions at the Lund Pelletron accelerator with the recently modified terminal pumping in use}}, url = {{http://dx.doi.org/10.1016/j.nima.2003.11.042}}, doi = {{10.1016/j.nima.2003.11.042}}, volume = {{521}}, year = {{2004}}, }