Quantification of structural differences in the human calvarium diploe by means of x-ray computed microtomography image analysis : A case study
(2011) In IFMBE Proceedings 37. p.599-602- Abstract
Accurate models for the human diploe have to take into account any structural differences in the four main areas of the calvaria bones. In this study the technique of Xray computed microtomography (μ-CT) along with image analysis was used in order to visualize and quantitatively analyze differences in the micro-architecture of the human calvarium diploe. A bone specimen from each area of the skull (temporal, frontal, parietal and occipital) was extracted from a human donor and each specimen was characterized in terms of density, specific surface area, trabecular thickness and anisotropy. The obtained results reveal that in the considered case there are structural differences which therefore can be useful for refining traditional models... (More)
Accurate models for the human diploe have to take into account any structural differences in the four main areas of the calvaria bones. In this study the technique of Xray computed microtomography (μ-CT) along with image analysis was used in order to visualize and quantitatively analyze differences in the micro-architecture of the human calvarium diploe. A bone specimen from each area of the skull (temporal, frontal, parietal and occipital) was extracted from a human donor and each specimen was characterized in terms of density, specific surface area, trabecular thickness and anisotropy. The obtained results reveal that in the considered case there are structural differences which therefore can be useful for refining traditional models that assume equal conditions throughout the skull.
(Less)
- author
- Larsson, E.
LU
; Brun, F. ; Tromba, G. ; Cataldi, P. ; Uvdal, K. and Accardo, A.
- publishing date
- 2011
- type
- Chapter in Book/Report/Conference proceeding
- publication status
- published
- keywords
- computed microtomography, diploe, image analysis, image processing
- host publication
- IFMBE Proceedings : 5th European Conference of the International Federation for Medical and Biological Engineering 14 - 18 September 2011, Budapest, Hungary - 5th European Conference of the International Federation for Medical and Biological Engineering 14 - 18 September 2011, Budapest, Hungary
- series title
- IFMBE Proceedings
- volume
- 37
- pages
- 599 - 602
- publisher
- Springer Nature
- external identifiers
-
- scopus:80455144926
- ISSN
- 1680-0737
- DOI
- 10.1007/978-3-642-23508-5_155
- language
- English
- LU publication?
- no
- id
- 4dd8bc47-65b7-4dfe-b4dd-d1bed66aaa03
- date added to LUP
- 2025-08-26 11:26:46
- date last changed
- 2025-08-26 11:48:07
@inproceedings{4dd8bc47-65b7-4dfe-b4dd-d1bed66aaa03, abstract = {{<p>Accurate models for the human diploe have to take into account any structural differences in the four main areas of the calvaria bones. In this study the technique of Xray computed microtomography (μ-CT) along with image analysis was used in order to visualize and quantitatively analyze differences in the micro-architecture of the human calvarium diploe. A bone specimen from each area of the skull (temporal, frontal, parietal and occipital) was extracted from a human donor and each specimen was characterized in terms of density, specific surface area, trabecular thickness and anisotropy. The obtained results reveal that in the considered case there are structural differences which therefore can be useful for refining traditional models that assume equal conditions throughout the skull.</p>}}, author = {{Larsson, E. and Brun, F. and Tromba, G. and Cataldi, P. and Uvdal, K. and Accardo, A.}}, booktitle = {{IFMBE Proceedings : 5th European Conference of the International Federation for Medical and Biological Engineering 14 - 18 September 2011, Budapest, Hungary}}, issn = {{1680-0737}}, keywords = {{computed microtomography; diploe; image analysis; image processing}}, language = {{eng}}, pages = {{599--602}}, publisher = {{Springer Nature}}, series = {{IFMBE Proceedings}}, title = {{Quantification of structural differences in the human calvarium diploe by means of x-ray computed microtomography image analysis : A case study}}, url = {{http://dx.doi.org/10.1007/978-3-642-23508-5_155}}, doi = {{10.1007/978-3-642-23508-5_155}}, volume = {{37}}, year = {{2011}}, }