Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Experimental investigations and correlation development of convective heat transfer in a rotating smooth channel

Hosseinalipour, S. M. ; Shahbazian, H. R. LU and Sunden, Bengt LU (2018) In Experimental Thermal and Fluid Science 94. p.316-328
Abstract

An experimental study has been carried out to investigate the effects of Coriolis force and centrifugal buoyancy force on convective heat transfer in a smooth cooling channel under rotating condition in a new rotation facility. The main motivation behind this work is to obtain required data for developing heat transfer correlations based on rotating state. In accordance with the open literature, four parameters, i.e.s Reynolds number, Rotation number, coolant Density Ratio and main flow direction were selected to study the influence on local heat transfer coefficient. Therefore, the investigation considered Reynolds number (Re) ranging from 5000 to 12,000, Rotation number (Ro) in the range of 0–0.15, Inlet Density Ratio (DR) between... (More)

An experimental study has been carried out to investigate the effects of Coriolis force and centrifugal buoyancy force on convective heat transfer in a smooth cooling channel under rotating condition in a new rotation facility. The main motivation behind this work is to obtain required data for developing heat transfer correlations based on rotating state. In accordance with the open literature, four parameters, i.e.s Reynolds number, Rotation number, coolant Density Ratio and main flow direction were selected to study the influence on local heat transfer coefficient. Therefore, the investigation considered Reynolds number (Re) ranging from 5000 to 12,000, Rotation number (Ro) in the range of 0–0.15, Inlet Density Ratio (DR) between 0.04 and 0.1 and at the entry developing region of a square smooth channel in a new rotation test bench. Comprehensive experiment have been conducted to collect data on the local Nusselt number at the leading and trailing walls. The results show that the local heat transfer rate is enhanced by rotation on the trailing surface and reduced on the leading surface in outward flow due to symmetrical secondary vortex generated by Coriolis force. The centrifugal buoyancy effect is favorable to the heat transfer enhancement on both walls. Also, by utilizing the extensive experimental data, correlations for the local Nusselt number have been updated for the leading and trailing walls in ranges of the mentioned flow parameters, which can be used as an internal cooling boundary condition for numerical analysis of thermal stresses and cooling efficiency maximization for gas turbine blades.

(Less)
Please use this url to cite or link to this publication:
author
; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Centrifugal buoyancy, Coriolis force, Correlation development, Rotating heat transfer, Square channel
in
Experimental Thermal and Fluid Science
volume
94
pages
13 pages
publisher
Elsevier
external identifiers
  • scopus:85042850764
ISSN
0894-1777
DOI
10.1016/j.expthermflusci.2018.02.020
language
English
LU publication?
yes
id
4e334580-6e73-4fc2-b79f-6460f1a80270
date added to LUP
2018-03-22 10:14:52
date last changed
2022-04-17 19:29:22
@article{4e334580-6e73-4fc2-b79f-6460f1a80270,
  abstract     = {{<p>An experimental study has been carried out to investigate the effects of Coriolis force and centrifugal buoyancy force on convective heat transfer in a smooth cooling channel under rotating condition in a new rotation facility. The main motivation behind this work is to obtain required data for developing heat transfer correlations based on rotating state. In accordance with the open literature, four parameters, i.e.s Reynolds number, Rotation number, coolant Density Ratio and main flow direction were selected to study the influence on local heat transfer coefficient. Therefore, the investigation considered Reynolds number (Re) ranging from 5000 to 12,000, Rotation number (Ro) in the range of 0–0.15, Inlet Density Ratio (DR) between 0.04 and 0.1 and at the entry developing region of a square smooth channel in a new rotation test bench. Comprehensive experiment have been conducted to collect data on the local Nusselt number at the leading and trailing walls. The results show that the local heat transfer rate is enhanced by rotation on the trailing surface and reduced on the leading surface in outward flow due to symmetrical secondary vortex generated by Coriolis force. The centrifugal buoyancy effect is favorable to the heat transfer enhancement on both walls. Also, by utilizing the extensive experimental data, correlations for the local Nusselt number have been updated for the leading and trailing walls in ranges of the mentioned flow parameters, which can be used as an internal cooling boundary condition for numerical analysis of thermal stresses and cooling efficiency maximization for gas turbine blades.</p>}},
  author       = {{Hosseinalipour, S. M. and Shahbazian, H. R. and Sunden, Bengt}},
  issn         = {{0894-1777}},
  keywords     = {{Centrifugal buoyancy; Coriolis force; Correlation development; Rotating heat transfer; Square channel}},
  language     = {{eng}},
  month        = {{06}},
  pages        = {{316--328}},
  publisher    = {{Elsevier}},
  series       = {{Experimental Thermal and Fluid Science}},
  title        = {{Experimental investigations and correlation development of convective heat transfer in a rotating smooth channel}},
  url          = {{http://dx.doi.org/10.1016/j.expthermflusci.2018.02.020}},
  doi          = {{10.1016/j.expthermflusci.2018.02.020}},
  volume       = {{94}},
  year         = {{2018}},
}