Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Second trimester cervical length measurements with transvaginal ultrasound : A prospective observational agreement and reliability study

Kuusela, Pihla ; Wennerholm, Ulla Britt ; Fadl, Helena ; Wesström, Jan ; Lindgren, Peter ; Hagberg, Henrik ; Jacobsson, Bo and Valentin, Lil LU orcid (2020) In Acta Obstetricia et Gynecologica Scandinavica 99(11). p.1475-1485
Abstract

Introduction: Universal screening for preterm delivery by adding transvaginal ultrasound measurement of cervical length to routine second trimester ultrasound has been proposed. The aim is to estimate inter- and intraobserver agreement and reliability of second trimester transvaginal ultrasound measurements of cervical length performed by specially trained midwife sonographers. Material and methods: This is a prospective reliability and agreement study performed in seven Swedish ultrasound centers. In total, 18 midwife sonographers specially trained to perform ultrasound measurements of cervical length and 286 women in the second trimester were included. In each center, two midwife sonographers measured cervical length a few minutes... (More)

Introduction: Universal screening for preterm delivery by adding transvaginal ultrasound measurement of cervical length to routine second trimester ultrasound has been proposed. The aim is to estimate inter- and intraobserver agreement and reliability of second trimester transvaginal ultrasound measurements of cervical length performed by specially trained midwife sonographers. Material and methods: This is a prospective reliability and agreement study performed in seven Swedish ultrasound centers. In total, 18 midwife sonographers specially trained to perform ultrasound measurements of cervical length and 286 women in the second trimester were included. In each center, two midwife sonographers measured cervical length a few minutes apart in the same woman, the number of women examined per examiner pair varying between 24 and 30 (LIVE study). Sixteen midwife sonographers measured cervical length twice ≥2 months apart on 93 video clips (CLIPS study). The main outcome measures were mean difference, limits of agreement, intraclass correlation coefficient, intra-individual standard deviation, repeatability, Cohen’s kappa and Fleiss kappa. Results: The limits of agreement and intraclass correlation coefficient of the best examiner pair in the LIVE study were −4.06 to 4.72 mm and 0.91, and those of the poorest were −11.11 to 11.39 mm and 0.31. In the CLIPS study, median (range) intra-individual standard deviation was 2.14 mm (1.40-3.46), repeatability 5.93 mm (3.88-9.58), intraclass correlation coefficient 0.84 (0.66-0.94). Median (range) interobserver agreement for cervical length ≤25 mm in the CLIPS study was 94.6% (84.9%-98.9%) and Cohen’s kappa 0.56 (0.12-0.92), median (range) intraobserver agreement was 95.2% (87.1%-98.9%) and Cohen’s kappa 0.68 (0.27-0.93). Conclusions: Agreement and reliability of cervical length measurements differed substantially between examiner pairs and examiners. If cervical length measurements are used to guide management there is potential for both over- and under-treatment. Uniform training and rigorous supervision and quality control are advised.

(Less)
Please use this url to cite or link to this publication:
author
; ; ; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
cervical length, cervical length measurement, data accuracy, inter-observer variation, intraobserver variation, preterm delivery, quality control, reproducibility of results, second trimester of pregnancy, transvaginal ultrasound
in
Acta Obstetricia et Gynecologica Scandinavica
volume
99
issue
11
pages
11 pages
publisher
Wiley-Blackwell
external identifiers
  • pmid:32392356
  • scopus:85085027437
ISSN
0001-6349
DOI
10.1111/aogs.13895
language
English
LU publication?
yes
id
4e740a1d-0089-4f43-a718-5cfbab6e72d9
date added to LUP
2020-06-26 11:03:26
date last changed
2024-05-29 15:14:31
@article{4e740a1d-0089-4f43-a718-5cfbab6e72d9,
  abstract     = {{<p>Introduction: Universal screening for preterm delivery by adding transvaginal ultrasound measurement of cervical length to routine second trimester ultrasound has been proposed. The aim is to estimate inter- and intraobserver agreement and reliability of second trimester transvaginal ultrasound measurements of cervical length performed by specially trained midwife sonographers. Material and methods: This is a prospective reliability and agreement study performed in seven Swedish ultrasound centers. In total, 18 midwife sonographers specially trained to perform ultrasound measurements of cervical length and 286 women in the second trimester were included. In each center, two midwife sonographers measured cervical length a few minutes apart in the same woman, the number of women examined per examiner pair varying between 24 and 30 (LIVE study). Sixteen midwife sonographers measured cervical length twice ≥2 months apart on 93 video clips (CLIPS study). The main outcome measures were mean difference, limits of agreement, intraclass correlation coefficient, intra-individual standard deviation, repeatability, Cohen’s kappa and Fleiss kappa. Results: The limits of agreement and intraclass correlation coefficient of the best examiner pair in the LIVE study were −4.06 to 4.72 mm and 0.91, and those of the poorest were −11.11 to 11.39 mm and 0.31. In the CLIPS study, median (range) intra-individual standard deviation was 2.14 mm (1.40-3.46), repeatability 5.93 mm (3.88-9.58), intraclass correlation coefficient 0.84 (0.66-0.94). Median (range) interobserver agreement for cervical length ≤25 mm in the CLIPS study was 94.6% (84.9%-98.9%) and Cohen’s kappa 0.56 (0.12-0.92), median (range) intraobserver agreement was 95.2% (87.1%-98.9%) and Cohen’s kappa 0.68 (0.27-0.93). Conclusions: Agreement and reliability of cervical length measurements differed substantially between examiner pairs and examiners. If cervical length measurements are used to guide management there is potential for both over- and under-treatment. Uniform training and rigorous supervision and quality control are advised.</p>}},
  author       = {{Kuusela, Pihla and Wennerholm, Ulla Britt and Fadl, Helena and Wesström, Jan and Lindgren, Peter and Hagberg, Henrik and Jacobsson, Bo and Valentin, Lil}},
  issn         = {{0001-6349}},
  keywords     = {{cervical length; cervical length measurement; data accuracy; inter-observer variation; intraobserver variation; preterm delivery; quality control; reproducibility of results; second trimester of pregnancy; transvaginal ultrasound}},
  language     = {{eng}},
  number       = {{11}},
  pages        = {{1475--1485}},
  publisher    = {{Wiley-Blackwell}},
  series       = {{Acta Obstetricia et Gynecologica Scandinavica}},
  title        = {{Second trimester cervical length measurements with transvaginal ultrasound : A prospective observational agreement and reliability study}},
  url          = {{http://dx.doi.org/10.1111/aogs.13895}},
  doi          = {{10.1111/aogs.13895}},
  volume       = {{99}},
  year         = {{2020}},
}