Monitoring Low Molecular Weight Heparins at Therapeutic Levels: Dose-Responses of, and Correlations and Differences between aPTT, Anti-Factor Xa and Thrombin Generation Assays.
(2015) In PLoS ONE 10(1).- Abstract
- Low molecular weight heparins (LMWH's) are used to prevent and treat thrombosis. Tests for monitoring LMWH's include anti-factor Xa (anti-FXa), activated partial thromboplastin time (aPTT) and thrombin generation. Anti-FXa is the current gold standard despite LMWH's varying affinities for FXa and thrombin.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/5039555
- author
- Thomas, Owain
LU
; Lybeck, Emanuel LU ; Strandberg, Karin LU ; Tynngård, Nahreen and Schött, Ulf LU
- organization
- publishing date
- 2015
- type
- Contribution to journal
- publication status
- published
- subject
- in
- PLoS ONE
- volume
- 10
- issue
- 1
- article number
- e0116835
- publisher
- Public Library of Science (PLoS)
- external identifiers
-
- pmid:25625201
- wos:000348821400018
- scopus:84921969922
- pmid:25625201
- ISSN
- 1932-6203
- DOI
- 10.1371/journal.pone.0116835
- project
- Koagulation vid kirurgi och kritisk sjukdom
- Haemostatic Safety in Epidural Analgesia
- language
- English
- LU publication?
- yes
- id
- 8e2ba9de-9387-4a07-8d65-3dc0a76955c1 (old id 5039555)
- alternative location
- http://www.ncbi.nlm.nih.gov/pubmed/25625201?dopt=Abstract
- date added to LUP
- 2016-04-01 13:20:00
- date last changed
- 2022-05-07 08:45:30
@article{8e2ba9de-9387-4a07-8d65-3dc0a76955c1, abstract = {{Low molecular weight heparins (LMWH's) are used to prevent and treat thrombosis. Tests for monitoring LMWH's include anti-factor Xa (anti-FXa), activated partial thromboplastin time (aPTT) and thrombin generation. Anti-FXa is the current gold standard despite LMWH's varying affinities for FXa and thrombin.}}, author = {{Thomas, Owain and Lybeck, Emanuel and Strandberg, Karin and Tynngård, Nahreen and Schött, Ulf}}, issn = {{1932-6203}}, language = {{eng}}, number = {{1}}, publisher = {{Public Library of Science (PLoS)}}, series = {{PLoS ONE}}, title = {{Monitoring Low Molecular Weight Heparins at Therapeutic Levels: Dose-Responses of, and Correlations and Differences between aPTT, Anti-Factor Xa and Thrombin Generation Assays.}}, url = {{https://lup.lub.lu.se/search/files/3307114/7753794}}, doi = {{10.1371/journal.pone.0116835}}, volume = {{10}}, year = {{2015}}, }