New improved method for 2D arterial wall movement measurements

Cinthio, Magnus LU ; Ahlgren, A ; Jansson, Tomas LU ; Persson, Hans W LU and Lindström, Kjell LU (2005) Proceedings of the International Federation for Medical & Biomedical Engineering. 13th Nordic Baltic Conference on Biomedical Engineering and Medical Physics p.117-118
Abstract
We have recently reported that the inner layers of the arteries, the intima-media complex, of common carotid artery, move as much in the longitudinal direction as in the radial direction, during the cardiac cycle. In order to study this phenomenon we have developed a high-resolution ultrasonic method that can simultaneously record both the longitudinal and the radial movements of the arterial wall non-invasively in vivo. However, in young individuals with large movements and with thin intima-media complex it happens sometimes that the echoes from the adventitia region interfere. To be able to minimise the size of the region-of-interest in the radial direction, we suggest that the radial movement of the arterial vessel is first measured and... (More)
We have recently reported that the inner layers of the arteries, the intima-media complex, of common carotid artery, move as much in the longitudinal direction as in the radial direction, during the cardiac cycle. In order to study this phenomenon we have developed a high-resolution ultrasonic method that can simultaneously record both the longitudinal and the radial movements of the arterial wall non-invasively in vivo. However, in young individuals with large movements and with thin intima-media complex it happens sometimes that the echoes from the adventitia region interfere. To be able to minimise the size of the region-of-interest in the radial direction, we suggest that the radial movement of the arterial vessel is first measured and that the radial movement is used as a priori information when the longitudinal movement is measured. The mean difference between the two methods is 8 and 2 standard deviation is 24 μm (Less)
Please use this url to cite or link to this publication:
author
; ; ; and
organization
publishing date
type
Chapter in Book/Report/Conference proceeding
publication status
published
subject
keywords
radial arterial wall movement measurement, echo interference, adventitia, longitudinal arterial wall movement measurement, high-resolution ultrasonic method, cardiac cycle, common carotid artery, 2D arterial wall movement measurement, intima-media complex
host publication
Proceedings of the International Federation for Medical & Biomedical Engineering. 13th Nordic Baltic Conference on Biomedical Engineering and Medical Physics
pages
117 - 118
publisher
Int. Federation for Medical and Biological Eng
conference name
Proceedings of the International Federation for Medical & Biomedical Engineering. 13th Nordic Baltic Conference on Biomedical Engineering and Medical Physics
conference location
Umea, Sweden
conference dates
2005-06-13 - 2005-06-17
ISBN
91-7305-910-2
language
English
LU publication?
yes
id
5a6f48ad-d683-4ad8-b32e-4262c36db196 (old id 616108)
date added to LUP
2016-04-04 11:10:17
date last changed
2018-11-21 21:03:05
@inproceedings{5a6f48ad-d683-4ad8-b32e-4262c36db196,
  abstract     = {{We have recently reported that the inner layers of the arteries, the intima-media complex, of common carotid artery, move as much in the longitudinal direction as in the radial direction, during the cardiac cycle. In order to study this phenomenon we have developed a high-resolution ultrasonic method that can simultaneously record both the longitudinal and the radial movements of the arterial wall non-invasively in vivo. However, in young individuals with large movements and with thin intima-media complex it happens sometimes that the echoes from the adventitia region interfere. To be able to minimise the size of the region-of-interest in the radial direction, we suggest that the radial movement of the arterial vessel is first measured and that the radial movement is used as a priori information when the longitudinal movement is measured. The mean difference between the two methods is 8 and 2 standard deviation is 24 μm}},
  author       = {{Cinthio, Magnus and Ahlgren, A and Jansson, Tomas and Persson, Hans W and Lindström, Kjell}},
  booktitle    = {{Proceedings of the International Federation for Medical & Biomedical Engineering. 13th Nordic Baltic Conference on Biomedical Engineering and Medical Physics}},
  isbn         = {{91-7305-910-2}},
  keywords     = {{radial arterial wall movement measurement; echo interference; adventitia; longitudinal arterial wall movement measurement; high-resolution ultrasonic method; cardiac cycle; common carotid artery; 2D arterial wall movement measurement; intima-media complex}},
  language     = {{eng}},