An efficient method to establish electrostatic screening lengths of restricted primitive model electrolytes
(2024) In Physical Chemistry Chemical Physics 26(29). p.19921-19933- Abstract
We present a novel, and computationally cheap, way to estimate electrostatic screening lengths from simulations of restricted primitive model (RPM) electrolytes. We demonstrate that the method is accurate by comparisons with simulated long-ranged parts of the charge density, at various Bjerrum lengths, salt concentrations and ion diameters. We find substantial underscreening in low dielectric solvent, but with an “aqueous” solvent, there is instead overscreening, the degree of which increases with ion size. Our method also offers a possible path to (future) more accurate classical density functional treatments of ionic fluids.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/5eed2a2a-cc80-434b-97ed-d262220769b1
- author
- Forsman, Jan LU ; Ribar, David LU and Woodward, Clifford E.
- organization
- publishing date
- 2024
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Physical Chemistry Chemical Physics
- volume
- 26
- issue
- 29
- pages
- 13 pages
- publisher
- Royal Society of Chemistry
- external identifiers
-
- pmid:38990567
- scopus:85199002086
- ISSN
- 1463-9076
- DOI
- 10.1039/d4cp00546e
- language
- English
- LU publication?
- yes
- additional info
- Publisher Copyright: © 2024 The Royal Society of Chemistry.
- id
- 5eed2a2a-cc80-434b-97ed-d262220769b1
- date added to LUP
- 2024-07-29 18:00:07
- date last changed
- 2024-11-19 06:32:24
@article{5eed2a2a-cc80-434b-97ed-d262220769b1, abstract = {{<p>We present a novel, and computationally cheap, way to estimate electrostatic screening lengths from simulations of restricted primitive model (RPM) electrolytes. We demonstrate that the method is accurate by comparisons with simulated long-ranged parts of the charge density, at various Bjerrum lengths, salt concentrations and ion diameters. We find substantial underscreening in low dielectric solvent, but with an “aqueous” solvent, there is instead overscreening, the degree of which increases with ion size. Our method also offers a possible path to (future) more accurate classical density functional treatments of ionic fluids.</p>}}, author = {{Forsman, Jan and Ribar, David and Woodward, Clifford E.}}, issn = {{1463-9076}}, language = {{eng}}, number = {{29}}, pages = {{19921--19933}}, publisher = {{Royal Society of Chemistry}}, series = {{Physical Chemistry Chemical Physics}}, title = {{An efficient method to establish electrostatic screening lengths of restricted primitive model electrolytes}}, url = {{http://dx.doi.org/10.1039/d4cp00546e}}, doi = {{10.1039/d4cp00546e}}, volume = {{26}}, year = {{2024}}, }