Optimisation of occupational radiological protection in image-guided interventions : potential impact of dose rate measurements

Almén, A LU ; Sandblom, V ; Båth, M and Lundh, C (2015) In Journal of Radiological Protection 35(1). p.47-62
Abstract

The optimisation of occupational radiological protection is challenging and a variety of factors have to be considered. Physicians performing image-guided interventions are working in an environment with one of the highest radiation risk levels in healthcare. Appropriate knowledge about the radiation environment is a prerequisite for conducting the optimisation process. Information about the dose rate variation during the interventions could provide valuable input to this process. The overall purpose of this study was to explore the prerequisite and feasibility to measure dose rate in scattered radiation and to assess the usefulness of such data in the optimisation process.Using an active dosimeter system, the dose rate in the... (More)

The optimisation of occupational radiological protection is challenging and a variety of factors have to be considered. Physicians performing image-guided interventions are working in an environment with one of the highest radiation risk levels in healthcare. Appropriate knowledge about the radiation environment is a prerequisite for conducting the optimisation process. Information about the dose rate variation during the interventions could provide valuable input to this process. The overall purpose of this study was to explore the prerequisite and feasibility to measure dose rate in scattered radiation and to assess the usefulness of such data in the optimisation process.Using an active dosimeter system, the dose rate in the unshielded scattered radiation field was measured in a fixed point close to the patient undergoing an image-guided intervention. The measurements were performed with a time resolution of one second and the dose rate data was continuously timed in a data log. In two treatment rooms, data was collected during a 6 month time period, resulting in data from 380 image-guided interventions and vascular treatments in the abdomen, arms and legs. These procedures were categorised into eight types according to the purpose of the treatment and the anatomical region involved.The dose rate varied substantially between treatment types, both regarding the levels and the distribution during the procedure. The maximum dose rate for different types of interventions varied typically between 5 and 100 mSv h(-1), but substantially higher and lower dose rates were also registered. The average dose rate during a complete procedure was however substantially lower and varied typically between 0.05 and 1 mSv h(-1). An analysis of the distribution disclosed that for a large part of the treatment types, the major amount of the total accumulated dose for a procedure was delivered in less than 10% of the exposure time and in less than 1% of the total procedure time.The present study shows that systematic dose rate measurements are feasible. Such measurements can be used to give a general indication of the exposure level to the staff and could serve as a first risk assessment tool when introducing new treatment types or x-ray equipment in the clinic. For example, it could provide an indication for when detailed eye dose measurements are needed. It also gives input to risk management considerations and the development of efficient routines for other radiological protection measures.

(Less)
Please use this url to cite or link to this publication:
author
; ; and
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Body Burden, Feasibility Studies, Health Personnel, Humans, Occupational Exposure/analysis, Radiation Dosage, Radiation Injuries/etiology, Radiation Protection/methods, Radiometry/methods, Surgery, Computer-Assisted/adverse effects, Sweden, X-Rays
in
Journal of Radiological Protection
volume
35
issue
1
pages
16 pages
publisher
IOP Publishing
external identifiers
  • scopus:84923876127
  • pmid:25517218
ISSN
1361-6498
DOI
10.1088/0952-4746/35/1/47
language
English
LU publication?
no
id
60d41251-6382-4b77-bb3b-70f56d0b67f4
date added to LUP
2018-06-16 21:16:32
date last changed
2024-01-14 22:00:16
@article{60d41251-6382-4b77-bb3b-70f56d0b67f4,
  abstract     = {{<p>The optimisation of occupational radiological protection is challenging and a variety of factors have to be considered. Physicians performing image-guided interventions are working in an environment with one of the highest radiation risk levels in healthcare. Appropriate knowledge about the radiation environment is a prerequisite for conducting the optimisation process. Information about the dose rate variation during the interventions could provide valuable input to this process. The overall purpose of this study was to explore the prerequisite and feasibility to measure dose rate in scattered radiation and to assess the usefulness of such data in the optimisation process.Using an active dosimeter system, the dose rate in the unshielded scattered radiation field was measured in a fixed point close to the patient undergoing an image-guided intervention. The measurements were performed with a time resolution of one second and the dose rate data was continuously timed in a data log. In two treatment rooms, data was collected during a 6 month time period, resulting in data from 380 image-guided interventions and vascular treatments in the abdomen, arms and legs. These procedures were categorised into eight types according to the purpose of the treatment and the anatomical region involved.The dose rate varied substantially between treatment types, both regarding the levels and the distribution during the procedure. The maximum dose rate for different types of interventions varied typically between 5 and 100 mSv h(-1), but substantially higher and lower dose rates were also registered. The average dose rate during a complete procedure was however substantially lower and varied typically between 0.05 and 1 mSv h(-1). An analysis of the distribution disclosed that for a large part of the treatment types, the major amount of the total accumulated dose for a procedure was delivered in less than 10% of the exposure time and in less than 1% of the total procedure time.The present study shows that systematic dose rate measurements are feasible. Such measurements can be used to give a general indication of the exposure level to the staff and could serve as a first risk assessment tool when introducing new treatment types or x-ray equipment in the clinic. For example, it could provide an indication for when detailed eye dose measurements are needed. It also gives input to risk management considerations and the development of efficient routines for other radiological protection measures. </p>}},
  author       = {{Almén, A and Sandblom, V and Båth, M and Lundh, C}},
  issn         = {{1361-6498}},
  keywords     = {{Body Burden; Feasibility Studies; Health Personnel; Humans; Occupational Exposure/analysis; Radiation Dosage; Radiation Injuries/etiology; Radiation Protection/methods; Radiometry/methods; Surgery, Computer-Assisted/adverse effects; Sweden; X-Rays}},
  language     = {{eng}},
  number       = {{1}},
  pages        = {{47--62}},
  publisher    = {{IOP Publishing}},
  series       = {{Journal of Radiological Protection}},
  title        = {{Optimisation of occupational radiological protection in image-guided interventions : potential impact of dose rate measurements}},
  url          = {{http://dx.doi.org/10.1088/0952-4746/35/1/47}},
  doi          = {{10.1088/0952-4746/35/1/47}},
  volume       = {{35}},
  year         = {{2015}},
}