Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

A Randomised RSA Study of Peri-Apatite [trademark] HA coating of a Knee Prosthesis

Hansson, Ulrik LU and Toksvig-Larsen, Sören LU (2004) The Annual Meeting of the International Society for Ceramics in Medicine 254-256. p.623-626
Abstract
Fifty knees scheduled for a total knee prosthesis were randomized in two groups. Both groups had a noncemented fixation of the porous-coated implants but one group received a prosthesis with ceramic coating on the porous surface of the implant. The knees were evaluated with RSA technique regarding micromotion the first two years. There were less micromotion in the coated group. The results indicate that the technique for ceramic coating here studied provides a safe and stable fixation of the implants.
Please use this url to cite or link to this publication:
author
and
organization
publishing date
type
Chapter in Book/Report/Conference proceeding
publication status
published
subject
keywords
Radiostereophotogrammetry (RSA), Maximal total point motion (MTPM)
host publication
Key Engineering Materials
volume
254-256
pages
623 - 626
publisher
Trans Tech Publications
conference name
The Annual Meeting of the International Society for Ceramics in Medicine
conference location
Porto, Portugal
conference dates
2003-11-06 - 2003-11-09
ISSN
1013-9826
language
English
LU publication?
yes
id
8b390526-aa51-46c1-aed2-a7eec80f40f2 (old id 614241)
alternative location
http://www.scientific.net/0-87849-932-6/623/
date added to LUP
2016-04-01 16:45:36
date last changed
2021-02-22 09:56:12
@inproceedings{8b390526-aa51-46c1-aed2-a7eec80f40f2,
  abstract     = {{Fifty knees scheduled for a total knee prosthesis were randomized in two groups. Both groups had a noncemented fixation of the porous-coated implants but one group received a prosthesis with ceramic coating on the porous surface of the implant. The knees were evaluated with RSA technique regarding micromotion the first two years. There were less micromotion in the coated group. The results indicate that the technique for ceramic coating here studied provides a safe and stable fixation of the implants.}},
  author       = {{Hansson, Ulrik and Toksvig-Larsen, Sören}},
  booktitle    = {{Key Engineering Materials}},
  issn         = {{1013-9826}},
  keywords     = {{Radiostereophotogrammetry (RSA); Maximal total point motion (MTPM)}},
  language     = {{eng}},
  pages        = {{623--626}},
  publisher    = {{Trans Tech Publications}},
  title        = {{A Randomised RSA Study of Peri-Apatite [trademark] HA coating of a Knee Prosthesis}},
  url          = {{http://www.scientific.net/0-87849-932-6/623/}},
  volume       = {{254-256}},
  year         = {{2004}},
}