Heparin binding protein in severe COVID-19- A prospective observational cohort study
(2021) In PLoS ONE 16(4 April).- Abstract
Background and aims Neutrophil-derived heparin binding protein (HBP; also known as azurocidin or CAP-37) is a key player in bacterial sepsis and a promising biomarker in severe infections. The aims of this study were to assess whether HBP is involved in the pathophysiology of COVID-19 and, if so, whether it can be used to predict severe disease preferably using a point-of-care test. Methods This was a prospective convenience sample study of biomarkers in patients admitted to Skåne University hospital in Sweden with a confirmed COVID-19 diagnosis. Plasma samples and clinical data were collected within 72h after admission, during hospital stay and at discharge. Plasma HBP concentrations samples were measured both with enzyme-linked... (More)
Background and aims Neutrophil-derived heparin binding protein (HBP; also known as azurocidin or CAP-37) is a key player in bacterial sepsis and a promising biomarker in severe infections. The aims of this study were to assess whether HBP is involved in the pathophysiology of COVID-19 and, if so, whether it can be used to predict severe disease preferably using a point-of-care test. Methods This was a prospective convenience sample study of biomarkers in patients admitted to Skåne University hospital in Sweden with a confirmed COVID-19 diagnosis. Plasma samples and clinical data were collected within 72h after admission, during hospital stay and at discharge. Plasma HBP concentrations samples were measured both with enzyme-linked immunosorbent assay (ELISA) and with a novel dry immunofluorescence analyzer (Joinstar) point-of-care test. Results Thirty-five COVID-19 patients were enrolled in the study. Twenty-nine patients had blood samples taken within 72h after admission. We compared the highest HBP value taken within 72h after admission in patients who eventually developed organ dysfunction (n = 23) compared to those who did not (n = 6), and found that HBP was significantly elevated in those who developed organ dysfunction (25.0 ng/mL (interquartile range (IQR) 16.6-48.5) vs 10.6 ng/mL (IQR 4.8-21.7 ng/mL), p = 0.03). Point-of-care test measurements correlated well with ELISA measurements (R = 0.83). HBP measured by the POC device predicted development of COVID-induced organ dysfunction with an AUC of 0.88 (95% confidence interval (CI) 0.70-1.0). Conclusions HBP is elevated prior to onset of organ dysfunction in patients with severe COVID-19 using a newly developed point-of-care test and hence HBP could be used in a clinical setting as a prognostic marker in COVID-19.
(Less)
- author
- Mellhammar, Lisa LU ; Thelaus, Louise LU ; Elen, Sixten ; Fisher, Jane LU and Linder, Adam LU
- organization
- publishing date
- 2021
- type
- Contribution to journal
- publication status
- published
- subject
- in
- PLoS ONE
- volume
- 16
- issue
- 4 April
- article number
- e0249570
- publisher
- Public Library of Science (PLoS)
- external identifiers
-
- scopus:85103995007
- pmid:33822821
- ISSN
- 1932-6203
- DOI
- 10.1371/journal.pone.0249570
- project
- Heparin binding protein and endothelial glycocalyx markers in severe COVID-19 – a prospective observational cohort study
- language
- English
- LU publication?
- yes
- id
- 616cefbb-2b5c-4d01-ba45-9a1803bcf8bd
- date added to LUP
- 2021-04-21 08:41:00
- date last changed
- 2024-09-21 19:14:59
@article{616cefbb-2b5c-4d01-ba45-9a1803bcf8bd, abstract = {{<p>Background and aims Neutrophil-derived heparin binding protein (HBP; also known as azurocidin or CAP-37) is a key player in bacterial sepsis and a promising biomarker in severe infections. The aims of this study were to assess whether HBP is involved in the pathophysiology of COVID-19 and, if so, whether it can be used to predict severe disease preferably using a point-of-care test. Methods This was a prospective convenience sample study of biomarkers in patients admitted to Skåne University hospital in Sweden with a confirmed COVID-19 diagnosis. Plasma samples and clinical data were collected within 72h after admission, during hospital stay and at discharge. Plasma HBP concentrations samples were measured both with enzyme-linked immunosorbent assay (ELISA) and with a novel dry immunofluorescence analyzer (Joinstar) point-of-care test. Results Thirty-five COVID-19 patients were enrolled in the study. Twenty-nine patients had blood samples taken within 72h after admission. We compared the highest HBP value taken within 72h after admission in patients who eventually developed organ dysfunction (n = 23) compared to those who did not (n = 6), and found that HBP was significantly elevated in those who developed organ dysfunction (25.0 ng/mL (interquartile range (IQR) 16.6-48.5) vs 10.6 ng/mL (IQR 4.8-21.7 ng/mL), p = 0.03). Point-of-care test measurements correlated well with ELISA measurements (R = 0.83). HBP measured by the POC device predicted development of COVID-induced organ dysfunction with an AUC of 0.88 (95% confidence interval (CI) 0.70-1.0). Conclusions HBP is elevated prior to onset of organ dysfunction in patients with severe COVID-19 using a newly developed point-of-care test and hence HBP could be used in a clinical setting as a prognostic marker in COVID-19.</p>}}, author = {{Mellhammar, Lisa and Thelaus, Louise and Elen, Sixten and Fisher, Jane and Linder, Adam}}, issn = {{1932-6203}}, language = {{eng}}, number = {{4 April}}, publisher = {{Public Library of Science (PLoS)}}, series = {{PLoS ONE}}, title = {{Heparin binding protein in severe COVID-19- A prospective observational cohort study}}, url = {{http://dx.doi.org/10.1371/journal.pone.0249570}}, doi = {{10.1371/journal.pone.0249570}}, volume = {{16}}, year = {{2021}}, }