Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Determination of trace levels of dinitrophenolic compounds by microporous membrane liquid-liquid extraction in environmental water samples

Bartolome, Luis ; Lezamiz, Jon LU ; Etxebarria, Nestor ; Zuloaga, Olatz and Jönsson, Jan Åke LU (2007) In Journal of Separation Science 30(13). p.2144-2152
Abstract
A fast and simple hollow fibre-based microporous membrane liquid-liquid extraction (MMLLE) method is proposed for the determination of trace levels of dinitrophenolic compounds in water samples. The optimization step was performed using a three-variables Doehlert matrix design, involving the fibre length, the quantity of trioctylphosphine oxide (TOPO) in the acceptor phase and the extraction time. Using the established experimental conditions, some other parameters such as stirring speed, salt content, humic acids and different organic solvents as the acceptor phase were studied. Validation of the method included calibration experiments, linearity studies and determination of method LOD (MLD). The RSD was around 11% in all the experiments... (More)
A fast and simple hollow fibre-based microporous membrane liquid-liquid extraction (MMLLE) method is proposed for the determination of trace levels of dinitrophenolic compounds in water samples. The optimization step was performed using a three-variables Doehlert matrix design, involving the fibre length, the quantity of trioctylphosphine oxide (TOPO) in the acceptor phase and the extraction time. Using the established experimental conditions, some other parameters such as stirring speed, salt content, humic acids and different organic solvents as the acceptor phase were studied. Validation of the method included calibration experiments, linearity studies and determination of method LOD (MLD). The RSD was around 11% in all the experiments on different days at different concentrations. Separation and detection of four dinitrophenols were performed in 10 min with an RP-LC and a C-8 column ACN-citric buffer gradient elution and diode array detection. (Less)
Please use this url to cite or link to this publication:
author
; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
water samples, MMLLE, dinitrophenols, HPLC-DAD
in
Journal of Separation Science
volume
30
issue
13
pages
2144 - 2152
publisher
John Wiley & Sons Inc.
external identifiers
  • wos:000249171200020
  • scopus:34548488457
ISSN
1615-9314
DOI
10.1002/jssc.200600509
language
English
LU publication?
yes
additional info
The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Analytical Chemistry (S/LTH) (011001004)
id
80d708e3-f184-414d-a495-42c856f7c155 (old id 687885)
date added to LUP
2016-04-01 11:40:39
date last changed
2022-01-26 08:33:50
@article{80d708e3-f184-414d-a495-42c856f7c155,
  abstract     = {{A fast and simple hollow fibre-based microporous membrane liquid-liquid extraction (MMLLE) method is proposed for the determination of trace levels of dinitrophenolic compounds in water samples. The optimization step was performed using a three-variables Doehlert matrix design, involving the fibre length, the quantity of trioctylphosphine oxide (TOPO) in the acceptor phase and the extraction time. Using the established experimental conditions, some other parameters such as stirring speed, salt content, humic acids and different organic solvents as the acceptor phase were studied. Validation of the method included calibration experiments, linearity studies and determination of method LOD (MLD). The RSD was around 11% in all the experiments on different days at different concentrations. Separation and detection of four dinitrophenols were performed in 10 min with an RP-LC and a C-8 column ACN-citric buffer gradient elution and diode array detection.}},
  author       = {{Bartolome, Luis and Lezamiz, Jon and Etxebarria, Nestor and Zuloaga, Olatz and Jönsson, Jan Åke}},
  issn         = {{1615-9314}},
  keywords     = {{water samples; MMLLE; dinitrophenols; HPLC-DAD}},
  language     = {{eng}},
  number       = {{13}},
  pages        = {{2144--2152}},
  publisher    = {{John Wiley & Sons Inc.}},
  series       = {{Journal of Separation Science}},
  title        = {{Determination of trace levels of dinitrophenolic compounds by microporous membrane liquid-liquid extraction in environmental water samples}},
  url          = {{http://dx.doi.org/10.1002/jssc.200600509}},
  doi          = {{10.1002/jssc.200600509}},
  volume       = {{30}},
  year         = {{2007}},
}