Experimental Investigations of a Low Weber Liquid Spray in Air Cross Flow
(2006) 10th International Conference on Liquid Atomization and Spray Systems- Abstract
- A Low Weber water spray subjected to an air cross flow has been investigated. The spray is characterized by low liquid injection velocity, producing a column that is broken up by aerodynamic forces from the oncoming air.PIV and PDA have been used to quantify both the continuous and dispersed phases. Long range microscopy has been used to characterize the column breakup process. It has been shown that bubbles (akin to droplet bag breakup) may form already in the column.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/715378
- author
- Eriksson, Pontus LU ; Orbay, Raik LU and Klingmann, Jens LU
- organization
- publishing date
- 2006
- type
- Chapter in Book/Report/Conference proceeding
- publication status
- published
- subject
- keywords
- Liquid Jet in Cross Flow, Low Weber Number, We, Bubble, Bag Breakup, Droplet, Liquid Atomization
- host publication
- [Host publication title missing]
- article number
- ICLASS06-277
- pages
- 7 pages
- publisher
- ICLASS
- conference name
- 10th International Conference on Liquid Atomization and Spray Systems
- conference dates
- 2006-08-27 - 2006-09-01
- external identifiers
-
- scopus:84874738175
- language
- English
- LU publication?
- yes
- id
- 7d9d5a76-5448-4718-8f1e-da44c12803f0 (old id 715378)
- alternative location
- http://www.ilasseurope.org/ICLASS/ICLASS2006/DATA/PDF/F4-04-277.pdf
- date added to LUP
- 2016-04-04 12:25:51
- date last changed
- 2022-01-29 23:24:59
@inproceedings{7d9d5a76-5448-4718-8f1e-da44c12803f0, abstract = {{A Low Weber water spray subjected to an air cross flow has been investigated. The spray is characterized by low liquid injection velocity, producing a column that is broken up by aerodynamic forces from the oncoming air.PIV and PDA have been used to quantify both the continuous and dispersed phases. Long range microscopy has been used to characterize the column breakup process. It has been shown that bubbles (akin to droplet bag breakup) may form already in the column.}}, author = {{Eriksson, Pontus and Orbay, Raik and Klingmann, Jens}}, booktitle = {{[Host publication title missing]}}, keywords = {{Liquid Jet in Cross Flow; Low Weber Number; We; Bubble; Bag Breakup; Droplet; Liquid Atomization}}, language = {{eng}}, publisher = {{ICLASS}}, title = {{Experimental Investigations of a Low Weber Liquid Spray in Air Cross Flow}}, url = {{http://www.ilasseurope.org/ICLASS/ICLASS2006/DATA/PDF/F4-04-277.pdf}}, year = {{2006}}, }