A linear soft tissue artefact model for human movement analysis : Proof of concept using in vivo data

Andersen, Michael S. ; Damsgaard, Michael ; Rasmussen, John ; Ramsey, Dan K. and Benoit, Daniel L. LU (2012) In Gait and Posture 35(4). p.606-611
Abstract

We investigated the accuracy of a linear soft tissue artefact (STA) model in human movement analysis. Simultaneously recorded bone-mounted pin and skin marker data for the thigh and shank during walking, cutting and hopping were used to measure and model the motion of the skin marker clusters within anatomical reference frames (ARFs). This linear model allows skin marker movements relative to the underlying bone contrary to a rigid-body assumption. The linear model parameters were computed through a principal component analysis, which revealed that 95% of the variance of the STA motion for the thigh was contained in the first four principal components for all three tasks and all subjects. For the shank, 95% of the variance was contained... (More)

We investigated the accuracy of a linear soft tissue artefact (STA) model in human movement analysis. Simultaneously recorded bone-mounted pin and skin marker data for the thigh and shank during walking, cutting and hopping were used to measure and model the motion of the skin marker clusters within anatomical reference frames (ARFs). This linear model allows skin marker movements relative to the underlying bone contrary to a rigid-body assumption. The linear model parameters were computed through a principal component analysis, which revealed that 95% of the variance of the STA motion for the thigh was contained in the first four principal components for all three tasks and all subjects. For the shank, 95% of the variance was contained in the first four principal components during walking and cutting and first five during hopping. For the thigh, the maximum residual artefact was reduced from 27.0. mm to 5.1. mm (walking), 22.7. mm to 3.0. mm (cutting) and 16.2. mm to 3.5. mm (hopping) compared to a rigid-body assumption. Similar reductions were observed for the shank: 24.2. mm to 1.9. mm (walking), 20.3. mm to 1.9. mm (cutting) and 14.7. mm to 1.8. mm (hopping). A geometric analysis of the first four principal components revealed that, within the ARFs, marker cluster STA is governed by rigid-body translations and rotations rather than deformations. The challenge remains, however, in finding the linear model parameters without bone pin data, but this investigation shows that relatively few parameters in a linear model are required to model the vast majority of the STA movements.

(Less)
Please use this url to cite or link to this publication:
author
; ; ; and
publishing date
type
Contribution to journal
publication status
published
keywords
In vivo, Kinematic model, Soft tissue artefacts
in
Gait and Posture
volume
35
issue
4
pages
606 - 611
publisher
Elsevier
external identifiers
  • scopus:84859217992
  • pmid:22225853
ISSN
0966-6362
DOI
10.1016/j.gaitpost.2011.11.032
language
English
LU publication?
no
id
7303120b-0a48-4c07-b48f-d0b66bdd1df6
date added to LUP
2023-08-24 16:52:15
date last changed
2025-04-20 12:31:15
@article{7303120b-0a48-4c07-b48f-d0b66bdd1df6,
  abstract     = {{<p>We investigated the accuracy of a linear soft tissue artefact (STA) model in human movement analysis. Simultaneously recorded bone-mounted pin and skin marker data for the thigh and shank during walking, cutting and hopping were used to measure and model the motion of the skin marker clusters within anatomical reference frames (ARFs). This linear model allows skin marker movements relative to the underlying bone contrary to a rigid-body assumption. The linear model parameters were computed through a principal component analysis, which revealed that 95% of the variance of the STA motion for the thigh was contained in the first four principal components for all three tasks and all subjects. For the shank, 95% of the variance was contained in the first four principal components during walking and cutting and first five during hopping. For the thigh, the maximum residual artefact was reduced from 27.0. mm to 5.1. mm (walking), 22.7. mm to 3.0. mm (cutting) and 16.2. mm to 3.5. mm (hopping) compared to a rigid-body assumption. Similar reductions were observed for the shank: 24.2. mm to 1.9. mm (walking), 20.3. mm to 1.9. mm (cutting) and 14.7. mm to 1.8. mm (hopping). A geometric analysis of the first four principal components revealed that, within the ARFs, marker cluster STA is governed by rigid-body translations and rotations rather than deformations. The challenge remains, however, in finding the linear model parameters without bone pin data, but this investigation shows that relatively few parameters in a linear model are required to model the vast majority of the STA movements.</p>}},
  author       = {{Andersen, Michael S. and Damsgaard, Michael and Rasmussen, John and Ramsey, Dan K. and Benoit, Daniel L.}},
  issn         = {{0966-6362}},
  keywords     = {{In vivo; Kinematic model; Soft tissue artefacts}},
  language     = {{eng}},
  number       = {{4}},
  pages        = {{606--611}},
  publisher    = {{Elsevier}},
  series       = {{Gait and Posture}},
  title        = {{A linear soft tissue artefact model for human movement analysis : Proof of concept using in vivo data}},
  url          = {{http://dx.doi.org/10.1016/j.gaitpost.2011.11.032}},
  doi          = {{10.1016/j.gaitpost.2011.11.032}},
  volume       = {{35}},
  year         = {{2012}},
}