Separation of 100-kilobase DNA molecules in 10 seconds
(2001) In Analytical Chemistry 73(24). p.6053-6056- Abstract
Long double-stranded DNA molecules were separated in microfabricated hexagonal arrays in less than 1 min, several orders of magnitude faster than by using conventional technology. DNA samples were first concentrated at the entrance to the array in a thin band by entropic focusing. They were then separated by pulsed field electrophoresis. T4 (168.9 kbp) and λ (48.5 kbp) DNAs could be resolved into two clearly separated bands in ∼10 s in these experiments. This corresponds to a mass resolution of 6% in 11 min in a 1-cm-long array.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/73a008d4-1f93-434f-8fbe-3c79b138adb8
- author
- Bakajin, O.
; Duke, T. A J
; Tegenfeldt, J.
LU
; Chou, C. F. ; Chan, S. S. LU ; Austin, R. H. and Cox, E. C.
- organization
- publishing date
- 2001-12-15
- type
- Contribution to journal
- publication status
- published
- in
- Analytical Chemistry
- volume
- 73
- issue
- 24
- pages
- 4 pages
- publisher
- The American Chemical Society (ACS)
- external identifiers
-
- pmid:11791579
- scopus:0035894044
- ISSN
- 0003-2700
- DOI
- 10.1021/ac015527o
- language
- English
- LU publication?
- yes
- id
- 73a008d4-1f93-434f-8fbe-3c79b138adb8
- date added to LUP
- 2018-10-20 10:42:23
- date last changed
- 2025-01-22 21:39:53
@article{73a008d4-1f93-434f-8fbe-3c79b138adb8, abstract = {{<p>Long double-stranded DNA molecules were separated in microfabricated hexagonal arrays in less than 1 min, several orders of magnitude faster than by using conventional technology. DNA samples were first concentrated at the entrance to the array in a thin band by entropic focusing. They were then separated by pulsed field electrophoresis. T4 (168.9 kbp) and λ (48.5 kbp) DNAs could be resolved into two clearly separated bands in ∼10 s in these experiments. This corresponds to a mass resolution of 6% in 11 min in a 1-cm-long array.</p>}}, author = {{Bakajin, O. and Duke, T. A J and Tegenfeldt, J. and Chou, C. F. and Chan, S. S. and Austin, R. H. and Cox, E. C.}}, issn = {{0003-2700}}, language = {{eng}}, month = {{12}}, number = {{24}}, pages = {{6053--6056}}, publisher = {{The American Chemical Society (ACS)}}, series = {{Analytical Chemistry}}, title = {{Separation of 100-kilobase DNA molecules in 10 seconds}}, url = {{http://dx.doi.org/10.1021/ac015527o}}, doi = {{10.1021/ac015527o}}, volume = {{73}}, year = {{2001}}, }