Quality assessment of digital X-ray chest images using an anthropomorphic chest phantom
(2017) In Journal of Physics: Conference Series 808(1).- Abstract
The current study is focused on determining the optimal tube voltage for the conventional X-ray digital chest screening examinations, using a visual grading analysis method. Chest images of an anthropomorphic phantom were acquired in posterior-anterior projection on four digital X-ray units with different detector types. X-ray images obtained with an anthropomorphic phantom were accepted by the radiologists as corresponding to a normal human anatomy, hence allowing using phantoms in image quality trials without limitations.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/74ae1cea-074a-4754-a646-96065fc5ee81
- author
- Vodovatov, A. V.
LU
; Kamishanskaya, I. G.
; Drozdov, A A
and Bernhardsson, C.
LU
- organization
- publishing date
- 2017-02-21
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Journal of Physics: Conference Series
- volume
- 808
- issue
- 1
- article number
- 012009
- publisher
- IOP Publishing
- external identifiers
-
- scopus:85016218103
- wos:000399921600010
- ISSN
- 1742-6588
- DOI
- 10.1088/1742-6596/808/1/012009
- project
- Radiation protection in Eastern Europe
- language
- English
- LU publication?
- yes
- id
- 74ae1cea-074a-4754-a646-96065fc5ee81
- date added to LUP
- 2017-04-06 08:11:12
- date last changed
- 2025-10-14 10:16:21
@article{74ae1cea-074a-4754-a646-96065fc5ee81,
abstract = {{<p>The current study is focused on determining the optimal tube voltage for the conventional X-ray digital chest screening examinations, using a visual grading analysis method. Chest images of an anthropomorphic phantom were acquired in posterior-anterior projection on four digital X-ray units with different detector types. X-ray images obtained with an anthropomorphic phantom were accepted by the radiologists as corresponding to a normal human anatomy, hence allowing using phantoms in image quality trials without limitations.</p>}},
author = {{Vodovatov, A. V. and Kamishanskaya, I. G. and Drozdov, A A and Bernhardsson, C.}},
issn = {{1742-6588}},
language = {{eng}},
month = {{02}},
number = {{1}},
publisher = {{IOP Publishing}},
series = {{Journal of Physics: Conference Series}},
title = {{Quality assessment of digital X-ray chest images using an anthropomorphic chest phantom}},
url = {{http://dx.doi.org/10.1088/1742-6596/808/1/012009}},
doi = {{10.1088/1742-6596/808/1/012009}},
volume = {{808}},
year = {{2017}},
}