A Method to Measure Shear Strain with High Spatial Resolution in the Arterial Wall Non-Invasively in vivo by Tracking Zero-Crossings of B-Mode Intensity Gradients

Erlöv, Tobias LU ; Rydén Ahlgren, Åsa LU ; Jansson, Tomas LU ; Persson, Hans W LU ; Nilsson, Jan LU ; Lindström, Kjell LU and Cinthio, Magnus LU (2010)
Abstract
We have previously shown that there is a distinct longitudinal movement of the arterial wall during a cardiac cycle. This movement is larger in the intima-media region than in the adventitial region which introduces a substantial shear strain within the arterial wall. Our previously developed echo-tracking algorithm measured this shear strain by tracking two separate echoes, one in the intima-media region and one in the adventitia region and thus only a linear distribution was evaluated. The objective of this study was to suggest and evaluate a new improved method which can measure the intramural shear strain with higher spatial resolution and thereby provide more information on this new and rather unknown phenomenon. The mean maximum... (More)
We have previously shown that there is a distinct longitudinal movement of the arterial wall during a cardiac cycle. This movement is larger in the intima-media region than in the adventitial region which introduces a substantial shear strain within the arterial wall. Our previously developed echo-tracking algorithm measured this shear strain by tracking two separate echoes, one in the intima-media region and one in the adventitia region and thus only a linear distribution was evaluated. The objective of this study was to suggest and evaluate a new improved method which can measure the intramural shear strain with higher spatial resolution and thereby provide more information on this new and rather unknown phenomenon. The mean maximum shear strain was 0.82 radians with a standard deviation of 0.17 radians and a CV-value of 14.2%. The total mean difference in measured longitudinal movement between the new and previous method was 10μm with a standard deviation of 90μm and a CV-value of 12.8%. The spatial distribution of the intramural shear strain seems to be very non-linear with a large amount of shear strain occurring in a small section around the transition between the media and adventitia layers. (Less)
Please use this url to cite or link to this publication:
author
organization
publishing date
type
Contribution to conference
publication status
published
subject
keywords
shear stress, longitudinal movement, carotid artery, non-invasive ultrasound
language
English
LU publication?
yes
id
a6db7c11-ee05-47d9-afc2-6d1f54521008 (old id 7793573)
date added to LUP
2015-12-15 10:40:31
date last changed
2016-04-16 12:16:26
@misc{a6db7c11-ee05-47d9-afc2-6d1f54521008,
  abstract     = {We have previously shown that there is a distinct longitudinal movement of the arterial wall during a cardiac cycle. This movement is larger in the intima-media region than in the adventitial region which introduces a substantial shear strain within the arterial wall. Our previously developed echo-tracking algorithm measured this shear strain by tracking two separate echoes, one in the intima-media region and one in the adventitia region and thus only a linear distribution was evaluated. The objective of this study was to suggest and evaluate a new improved method which can measure the intramural shear strain with higher spatial resolution and thereby provide more information on this new and rather unknown phenomenon. The mean maximum shear strain was 0.82 radians with a standard deviation of 0.17 radians and a CV-value of 14.2%. The total mean difference in measured longitudinal movement between the new and previous method was 10μm with a standard deviation of 90μm and a CV-value of 12.8%. The spatial distribution of the intramural shear strain seems to be very non-linear with a large amount of shear strain occurring in a small section around the transition between the media and adventitia layers.},
  author       = {Erlöv, Tobias and Rydén Ahlgren, Åsa and Jansson, Tomas and Persson, Hans W and Nilsson, Jan and Lindström, Kjell and Cinthio, Magnus},
  keyword      = {shear stress,longitudinal movement,carotid artery,non-invasive ultrasound},
  language     = {eng},
  title        = {A Method to Measure Shear Strain with High Spatial Resolution in the Arterial Wall Non-Invasively in vivo by Tracking Zero-Crossings of B-Mode Intensity Gradients},
  year         = {2010},
}