Saturation Dependence of Flame Thermometry by Mid-IR Degenerate Four Wave Mixing
(2021) In Applied Spectroscopy 75(1). p.107-114- Abstract
It has previously been demonstrated that the ratio of the degenerate four wave mixing signal from two hot water line groups near 3231 cm–1 can be used for seedless flame temperature measurements. This paper presents an investigation of the impact of saturation effects on the measured signal intensity from each line group, as well as an estimation of the accuracy of the method. The saturation effects observed here would result in a large systematic error if they are not taken into account when using the degenerate four-wave mixing intensity of these water line groups to calculate the flame temperature.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/78e30dd3-05b8-46d7-a281-8b8e8f74fb9a
- author
- Pedersen, Rasmus L.
LU
; Sahlberg, Anna Lena
LU
; Hot, Dina LU and Li, Zhongshan LU
- organization
- publishing date
- 2021
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- flame, infrared degenerate four-wave mixing, IR-DFWM, Saturation, thermometry, water
- in
- Applied Spectroscopy
- volume
- 75
- issue
- 1
- pages
- 107 - 114
- publisher
- Society for Applied Spectroscopy
- external identifiers
-
- scopus:85092190059
- pmid:33021109
- ISSN
- 0003-7028
- DOI
- 10.1177/0003702820955186
- language
- English
- LU publication?
- yes
- id
- 78e30dd3-05b8-46d7-a281-8b8e8f74fb9a
- date added to LUP
- 2020-11-19 12:04:41
- date last changed
- 2025-01-10 22:25:52
@article{78e30dd3-05b8-46d7-a281-8b8e8f74fb9a, abstract = {{<p>It has previously been demonstrated that the ratio of the degenerate four wave mixing signal from two hot water line groups near 3231 cm<sup>–1</sup> can be used for seedless flame temperature measurements. This paper presents an investigation of the impact of saturation effects on the measured signal intensity from each line group, as well as an estimation of the accuracy of the method. The saturation effects observed here would result in a large systematic error if they are not taken into account when using the degenerate four-wave mixing intensity of these water line groups to calculate the flame temperature.</p>}}, author = {{Pedersen, Rasmus L. and Sahlberg, Anna Lena and Hot, Dina and Li, Zhongshan}}, issn = {{0003-7028}}, keywords = {{flame; infrared degenerate four-wave mixing; IR-DFWM; Saturation; thermometry; water}}, language = {{eng}}, number = {{1}}, pages = {{107--114}}, publisher = {{Society for Applied Spectroscopy}}, series = {{Applied Spectroscopy}}, title = {{Saturation Dependence of Flame Thermometry by Mid-IR Degenerate Four Wave Mixing}}, url = {{https://lup.lub.lu.se/search/files/119436555/Pedersen_Appl_Spec_75_2021.pdf}}, doi = {{10.1177/0003702820955186}}, volume = {{75}}, year = {{2021}}, }