Lav-flow-anaestesisystemer

Reinstrup, Peter LU ; Slots, P and Jorgensen, B C (1992) In Ugeskrift for Læger 154(50). p.3577-3579
Abstract
At present, when economy and environment receive high priority, the ideal anaesthesia system with inhalation anaesthetics is a closed circle system in which only the gases which the patient consumes or produces are replaced or eliminated. Low-flow (LF) anaesthesia in which the fresh gas flow which is employed in a closed system, provides a stable system compares with closed anaesthesia systems. Compared with open systems and circler systems with considerable fresh gas flow, the LF system provides advantages as regards economy, environment and exposure of staff to inhalation anaesthetics. The special conditions involved in LF anaesthesia are described in detail with the hope that the method will obtain more widespread distribution than is... (More)
At present, when economy and environment receive high priority, the ideal anaesthesia system with inhalation anaesthetics is a closed circle system in which only the gases which the patient consumes or produces are replaced or eliminated. Low-flow (LF) anaesthesia in which the fresh gas flow which is employed in a closed system, provides a stable system compares with closed anaesthesia systems. Compared with open systems and circler systems with considerable fresh gas flow, the LF system provides advantages as regards economy, environment and exposure of staff to inhalation anaesthetics. The special conditions involved in LF anaesthesia are described in detail with the hope that the method will obtain more widespread distribution than is the case in Denmark today. If greater safety under anaesthesia is desired, eg by monitoring the concentrations of CO2, O2 and inhalation anaesthetics which the patients inspire and expire, this monitoring equipment can be financed by introduction of LF anaesthesia. (Less)
Please use this url to cite or link to this publication:
author
; and
organization
alternative title
Low-flow anesthesia systems
publishing date
type
Contribution to journal
publication status
published
subject
in
Ugeskrift for Læger
volume
154
issue
50
pages
3577 - 3579
publisher
Den Almindelige Danske Lægeforening
external identifiers
  • pmid:1471275
  • scopus:0027114647
ISSN
0041-5782
language
Danish
LU publication?
yes
id
7da7d2fe-9eaa-4064-a509-2155cdd7138f (old id 1106520)
date added to LUP
2016-04-01 15:48:21
date last changed
2021-01-03 03:34:41
@article{7da7d2fe-9eaa-4064-a509-2155cdd7138f,
  abstract     = {{At present, when economy and environment receive high priority, the ideal anaesthesia system with inhalation anaesthetics is a closed circle system in which only the gases which the patient consumes or produces are replaced or eliminated. Low-flow (LF) anaesthesia in which the fresh gas flow which is employed in a closed system, provides a stable system compares with closed anaesthesia systems. Compared with open systems and circler systems with considerable fresh gas flow, the LF system provides advantages as regards economy, environment and exposure of staff to inhalation anaesthetics. The special conditions involved in LF anaesthesia are described in detail with the hope that the method will obtain more widespread distribution than is the case in Denmark today. If greater safety under anaesthesia is desired, eg by monitoring the concentrations of CO2, O2 and inhalation anaesthetics which the patients inspire and expire, this monitoring equipment can be financed by introduction of LF anaesthesia.}},
  author       = {{Reinstrup, Peter and Slots, P and Jorgensen, B C}},
  issn         = {{0041-5782}},
  language     = {{dan}},
  number       = {{50}},
  pages        = {{3577--3579}},
  publisher    = {{Den Almindelige Danske Lægeforening}},
  series       = {{Ugeskrift for Læger}},
  title        = {{Lav-flow-anaestesisystemer}},
  volume       = {{154}},
  year         = {{1992}},
}