Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Water diffusion into and electrical testing of composite insulator GRP rods

Armentrout, D. ; Kumosa, M. and Kumosa, L. LU (2004) In IEEE Transactions on Dielectrics and Electrical Insulation 11(3). p.506-522
Abstract

This paper describes water diffusion into and electrical testing of unidirectional glass reinforced polymer (GRP) composite rods used as load bearing components in high voltage composite (non-ceramic) insulators. The tests were performed following ANSI standard C29.11 Section 7.4.2 that can be used to evaluate electrical properties of composites. The unidirectional composite rod materials based on either E-glass or ECR-glass fibers with modified polyester, epoxy and vinyl ester resins were investigated. Two types of ECR-glass fibers were considered, namely high and low seed (voids). The effects of composite surface sandblasting, mechanical pre-loading and nitric acid exposure on the electrical properties of the composites were studied.... (More)

This paper describes water diffusion into and electrical testing of unidirectional glass reinforced polymer (GRP) composite rods used as load bearing components in high voltage composite (non-ceramic) insulators. The tests were performed following ANSI standard C29.11 Section 7.4.2 that can be used to evaluate electrical properties of composites. The unidirectional composite rod materials based on either E-glass or ECR-glass fibers with modified polyester, epoxy and vinyl ester resins were investigated. Two types of ECR-glass fibers were considered, namely high and low seed (voids). The effects of composite surface sandblasting, mechanical pre-loading and nitric acid exposure on the electrical properties of the composites were studied. In addition to the required data of the ANSI standard, the specimen mass gain was also measured after boiling for 100 h. Most importantly, there was no correlation found between the mass gain and the leakage current for different composites. The materials with high seed ECR-glass fibers had much higher leakage currents and they absorbed less moisture than the composites based on either the low seed ECR-glass fibers or E-glass fibers. It was shown in this work that different types of sandblasting, as well as mechanical preloading with and without acid exposure had a negligible effect on the leakage currents and water mass gain of the composite specimens.

(Less)
Please use this url to cite or link to this publication:
author
; and
publishing date
type
Contribution to journal
publication status
published
keywords
Composite insulators, Glass reinforced polymer, GRP rods, Leakage current, Mechanical pre-loading, Nitric acid exposure, Non-ceramic insulators, Sand blasting, Water diffusion
in
IEEE Transactions on Dielectrics and Electrical Insulation
volume
11
issue
3
pages
506 - 522
publisher
IEEE - Institute of Electrical and Electronics Engineers Inc.
external identifiers
  • scopus:3142730493
ISSN
1070-9878
DOI
10.1109/TDEI.2004.1306729
language
English
LU publication?
no
id
7de6d5b0-22c3-4b09-b73f-53277fa0bf73
date added to LUP
2022-11-26 13:30:13
date last changed
2022-11-28 08:48:24
@article{7de6d5b0-22c3-4b09-b73f-53277fa0bf73,
  abstract     = {{<p>This paper describes water diffusion into and electrical testing of unidirectional glass reinforced polymer (GRP) composite rods used as load bearing components in high voltage composite (non-ceramic) insulators. The tests were performed following ANSI standard C29.11 Section 7.4.2 that can be used to evaluate electrical properties of composites. The unidirectional composite rod materials based on either E-glass or ECR-glass fibers with modified polyester, epoxy and vinyl ester resins were investigated. Two types of ECR-glass fibers were considered, namely high and low seed (voids). The effects of composite surface sandblasting, mechanical pre-loading and nitric acid exposure on the electrical properties of the composites were studied. In addition to the required data of the ANSI standard, the specimen mass gain was also measured after boiling for 100 h. Most importantly, there was no correlation found between the mass gain and the leakage current for different composites. The materials with high seed ECR-glass fibers had much higher leakage currents and they absorbed less moisture than the composites based on either the low seed ECR-glass fibers or E-glass fibers. It was shown in this work that different types of sandblasting, as well as mechanical preloading with and without acid exposure had a negligible effect on the leakage currents and water mass gain of the composite specimens.</p>}},
  author       = {{Armentrout, D. and Kumosa, M. and Kumosa, L.}},
  issn         = {{1070-9878}},
  keywords     = {{Composite insulators; Glass reinforced polymer; GRP rods; Leakage current; Mechanical pre-loading; Nitric acid exposure; Non-ceramic insulators; Sand blasting; Water diffusion}},
  language     = {{eng}},
  number       = {{3}},
  pages        = {{506--522}},
  publisher    = {{IEEE - Institute of Electrical and Electronics Engineers Inc.}},
  series       = {{IEEE Transactions on Dielectrics and Electrical Insulation}},
  title        = {{Water diffusion into and electrical testing of composite insulator GRP rods}},
  url          = {{http://dx.doi.org/10.1109/TDEI.2004.1306729}},
  doi          = {{10.1109/TDEI.2004.1306729}},
  volume       = {{11}},
  year         = {{2004}},
}