Chimney Grafts in Aortic Stent Grafting: Hazardous or Useful Technique? Systematic Review of Current Data.

Lindblad, Bengt LU ; BinJabr, Adel LU ; Holst, Jan LU and Malina, Martin LU (2015) In European Journal of Vascular and Endovascular Surgery 50(6). p.722-731
Abstract
The chimney graft (CG) technique was introduced to rescue accidentally covered aortic branches during aortic endovascular repair. It extends the sealing zone. There is concern about "gutter" type I endoleak (EL-I) and about the durability of CGs. The aim of the present report was to analyze the rapidly increasing existing data.
Please use this url to cite or link to this publication:
author
; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
European Journal of Vascular and Endovascular Surgery
volume
50
issue
6
pages
722 - 731
publisher
Elsevier
external identifiers
  • pmid:26371416
  • wos:000367105700010
  • scopus:84941695204
  • pmid:26371416
ISSN
1532-2165
DOI
10.1016/j.ejvs.2015.07.038
language
English
LU publication?
yes
id
457bcd88-fd6e-4e53-8129-6c6bc034509c (old id 8041975)
alternative location
http://www.ncbi.nlm.nih.gov/pubmed/26371416?dopt=Abstract
date added to LUP
2016-04-01 10:19:13
date last changed
2022-04-27 20:44:49
@article{457bcd88-fd6e-4e53-8129-6c6bc034509c,
  abstract     = {{The chimney graft (CG) technique was introduced to rescue accidentally covered aortic branches during aortic endovascular repair. It extends the sealing zone. There is concern about "gutter" type I endoleak (EL-I) and about the durability of CGs. The aim of the present report was to analyze the rapidly increasing existing data.}},
  author       = {{Lindblad, Bengt and BinJabr, Adel and Holst, Jan and Malina, Martin}},
  issn         = {{1532-2165}},
  language     = {{eng}},
  number       = {{6}},
  pages        = {{722--731}},
  publisher    = {{Elsevier}},
  series       = {{European Journal of Vascular and Endovascular Surgery}},
  title        = {{Chimney Grafts in Aortic Stent Grafting: Hazardous or Useful Technique? Systematic Review of Current Data.}},
  url          = {{http://dx.doi.org/10.1016/j.ejvs.2015.07.038}},
  doi          = {{10.1016/j.ejvs.2015.07.038}},
  volume       = {{50}},
  year         = {{2015}},
}