Pulmonary interstitial pressure in intact in situ lung: transition to interstitial edema

Miserocchi, G ; Negrini, D ; Del Fabbro, M and Venturoli, Daniele LU (1993) In Journal of Applied Physiology 74(3). p.1171-1177
Abstract
In anesthetized rabbits (n = 25) subject to slow intravenous saline loading (0.4 ml.min-1.kg-1) for 3 h, we measured pulmonary interstitial pressure (Pip) in intact in situ lungs with glass micropipettes inserted directly into the lung parenchyma via a "pleural window." Measurements were done in apneic animals at the end-expiratory volume with O2 delivered in the trachea. Pip was -10 +/- 1.5 (SD) cmH2O in control and increased to 0.6 +/- 3.8 and 5.7 +/- 3.3 cmH2O at 66 and 180 min, respectively. The wet-to-dry weight ratio (W/D) of the lung was 5.04 +/- 0.2 in the control group and 5.34 +/- 0.7 at 180 min (+6%); the corresponding W/D for intercostal muscles were 3.25 +/- 0.03 and 4.19 +/- 0.5 (+28%). Pulmonary interstitial compliance was... (More)
In anesthetized rabbits (n = 25) subject to slow intravenous saline loading (0.4 ml.min-1.kg-1) for 3 h, we measured pulmonary interstitial pressure (Pip) in intact in situ lungs with glass micropipettes inserted directly into the lung parenchyma via a "pleural window." Measurements were done in apneic animals at the end-expiratory volume with O2 delivered in the trachea. Pip was -10 +/- 1.5 (SD) cmH2O in control and increased to 0.6 +/- 3.8 and 5.7 +/- 3.3 cmH2O at 66 and 180 min, respectively. The wet-to-dry weight ratio (W/D) of the lung was 5.04 +/- 0.2 in the control group and 5.34 +/- 0.7 at 180 min (+6%); the corresponding W/D for intercostal muscles were 3.25 +/- 0.03 and 4.19 +/- 0.5 (+28%). Pulmonary interstitial compliance was 0.47 ml.mmHg-1.100 g wet wt-1. Pulmonary arterial and left atrial pressures were 18.4 +/- 2 and 3 +/- 1 cmH2O in control and increased to 19.5 +/- 2.9 and 4.6 +/- 1.7 cmH2O at 180 min, respectively. Aortic flow (cardiac output) increased from 103 +/- 35 to 131 +/- 26 ml/min; pulmonary resistance fell from 0.17 +/- 0.06 to 0.14 +/- 0.05 cmH2O.min.ml-1 (-18%), suggesting that the increase in Pip did not limit blood flow. The pulmonary capillary-to-interstitium filtration pressure gradient decreased sharply from a control value of 10 cmH2O to 0 cmH2O within 60 min because of the increase in Pip and remained unchanged for < or = 180 min. Data suggest that the pulmonary interstitial matrix can withstand fluid pressures above atmospheric, preventing the development of pulmonary alveolar flooding. (Less)
Please use this url to cite or link to this publication:
author
; ; and
publishing date
type
Contribution to journal
publication status
published
subject
in
Journal of Applied Physiology
volume
74
issue
3
pages
1171 - 1177
publisher
American Physiological Society
external identifiers
  • pmid:8482655
  • scopus:0027513906
ISSN
1522-1601
language
English
LU publication?
no
id
820faaec-e419-4b1c-878a-af5e79cde3ba (old id 1107174)
alternative location
http://jap.physiology.org/cgi/reprint/74/3/1171
date added to LUP
2016-04-01 11:52:01
date last changed
2021-09-19 04:17:50
@article{820faaec-e419-4b1c-878a-af5e79cde3ba,
  abstract     = {{In anesthetized rabbits (n = 25) subject to slow intravenous saline loading (0.4 ml.min-1.kg-1) for 3 h, we measured pulmonary interstitial pressure (Pip) in intact in situ lungs with glass micropipettes inserted directly into the lung parenchyma via a "pleural window." Measurements were done in apneic animals at the end-expiratory volume with O2 delivered in the trachea. Pip was -10 +/- 1.5 (SD) cmH2O in control and increased to 0.6 +/- 3.8 and 5.7 +/- 3.3 cmH2O at 66 and 180 min, respectively. The wet-to-dry weight ratio (W/D) of the lung was 5.04 +/- 0.2 in the control group and 5.34 +/- 0.7 at 180 min (+6%); the corresponding W/D for intercostal muscles were 3.25 +/- 0.03 and 4.19 +/- 0.5 (+28%). Pulmonary interstitial compliance was 0.47 ml.mmHg-1.100 g wet wt-1. Pulmonary arterial and left atrial pressures were 18.4 +/- 2 and 3 +/- 1 cmH2O in control and increased to 19.5 +/- 2.9 and 4.6 +/- 1.7 cmH2O at 180 min, respectively. Aortic flow (cardiac output) increased from 103 +/- 35 to 131 +/- 26 ml/min; pulmonary resistance fell from 0.17 +/- 0.06 to 0.14 +/- 0.05 cmH2O.min.ml-1 (-18%), suggesting that the increase in Pip did not limit blood flow. The pulmonary capillary-to-interstitium filtration pressure gradient decreased sharply from a control value of 10 cmH2O to 0 cmH2O within 60 min because of the increase in Pip and remained unchanged for &lt; or = 180 min. Data suggest that the pulmonary interstitial matrix can withstand fluid pressures above atmospheric, preventing the development of pulmonary alveolar flooding.}},
  author       = {{Miserocchi, G and Negrini, D and Del Fabbro, M and Venturoli, Daniele}},
  issn         = {{1522-1601}},
  language     = {{eng}},
  number       = {{3}},
  pages        = {{1171--1177}},