Dosimetric benefit of DMLC tracking for conventional and sub-volume boosted prostate intensity-modulated arc radiotherapy

Pommer, Tobias ; Falk, Marianne ; Poulsen, Per R. ; Keall, Paul J. ; O'Brien, Ricky T. ; Petersen, Peter Meidahl and Rosenschöld, Per Munck Af LU orcid (2013) In Physics in Medicine and Biology 58(7). p.2349-2361
Abstract

This study investigated the dosimetric impact of uncompensated motion and motion compensation with dynamic multileaf collimator (DMLC) tracking for prostate intensity modulated arc therapy. Two treatment approaches were investigated; a conventional approach with a uniform radiation dose to the target volume and an intraprostatic lesion (IPL) boosted approach with an increased dose to a subvolume of the prostate. The impact on plan quality of optimizations with a leaf position constraint, which limited the distance between neighbouring adjacent MLC leaves, was also investigated. Deliveries were done with and without DMLC tracking on a linear acceleration with a high-resolution MLC. A cylindrical phantom containing two orthogonal diode... (More)

This study investigated the dosimetric impact of uncompensated motion and motion compensation with dynamic multileaf collimator (DMLC) tracking for prostate intensity modulated arc therapy. Two treatment approaches were investigated; a conventional approach with a uniform radiation dose to the target volume and an intraprostatic lesion (IPL) boosted approach with an increased dose to a subvolume of the prostate. The impact on plan quality of optimizations with a leaf position constraint, which limited the distance between neighbouring adjacent MLC leaves, was also investigated. Deliveries were done with and without DMLC tracking on a linear acceleration with a high-resolution MLC. A cylindrical phantom containing two orthogonal diode arrays was used for dosimetry. A motion platform reproduced six patient-derived prostate motion traces, with the average displacement ranging from 1.0 to 8.9 mm during the first 75 s. A research DMLC tracking system was used for real-time motion compensation with optical monitoring for position input. The gamma index was used for evaluation, with measurements with a static phantom or the planned dose as reference, using 2% and 2 mm gamma criteria. The average pass rate with DMLC tracking was 99.9% (range 98.7-100%, measurement as reference), whereas the pass rate for untracked deliveries decreased distinctly as the average displacement increased, with an average pass rate of 61.3% (range 32.7-99.3%). Dose-volume histograms showed that DMLC tracking maintained the planned dose distributions in the presence of motion whereas traces with >3 mm average displacement caused clear plan degradation for untracked deliveries. The dose to the rectum and bladder had an evident dependence on the motion direction and amplitude for untracked deliveries, and the dose to the rectum was slightly increased for IPL boosted plans compared to conventional plans for anterior motion with large amplitude. In conclusion, optimization using a leaf position constraint had minimal dosimetric effect, DMLC tracking improved the target and normal tissue dose distributions compared to no tracking for target motion >3 mm, with the DMLC tracking distributions showing generally good agreement between the planned and delivered doses.

(Less)
Please use this url to cite or link to this publication:
author
; ; ; ; ; and
publishing date
type
Contribution to journal
publication status
published
subject
in
Physics in Medicine and Biology
volume
58
issue
7
pages
2349 - 2361
publisher
IOP Publishing
external identifiers
  • pmid:23492899
  • scopus:84875358697
ISSN
0031-9155
DOI
10.1088/0031-9155/58/7/2349
language
English
LU publication?
no
id
836e7497-b20d-4d62-b515-1bfd782246c8
date added to LUP
2023-07-19 17:06:14
date last changed
2024-02-03 15:18:57
@article{836e7497-b20d-4d62-b515-1bfd782246c8,
  abstract     = {{<p>This study investigated the dosimetric impact of uncompensated motion and motion compensation with dynamic multileaf collimator (DMLC) tracking for prostate intensity modulated arc therapy. Two treatment approaches were investigated; a conventional approach with a uniform radiation dose to the target volume and an intraprostatic lesion (IPL) boosted approach with an increased dose to a subvolume of the prostate. The impact on plan quality of optimizations with a leaf position constraint, which limited the distance between neighbouring adjacent MLC leaves, was also investigated. Deliveries were done with and without DMLC tracking on a linear acceleration with a high-resolution MLC. A cylindrical phantom containing two orthogonal diode arrays was used for dosimetry. A motion platform reproduced six patient-derived prostate motion traces, with the average displacement ranging from 1.0 to 8.9 mm during the first 75 s. A research DMLC tracking system was used for real-time motion compensation with optical monitoring for position input. The gamma index was used for evaluation, with measurements with a static phantom or the planned dose as reference, using 2% and 2 mm gamma criteria. The average pass rate with DMLC tracking was 99.9% (range 98.7-100%, measurement as reference), whereas the pass rate for untracked deliveries decreased distinctly as the average displacement increased, with an average pass rate of 61.3% (range 32.7-99.3%). Dose-volume histograms showed that DMLC tracking maintained the planned dose distributions in the presence of motion whereas traces with &gt;3 mm average displacement caused clear plan degradation for untracked deliveries. The dose to the rectum and bladder had an evident dependence on the motion direction and amplitude for untracked deliveries, and the dose to the rectum was slightly increased for IPL boosted plans compared to conventional plans for anterior motion with large amplitude. In conclusion, optimization using a leaf position constraint had minimal dosimetric effect, DMLC tracking improved the target and normal tissue dose distributions compared to no tracking for target motion &gt;3 mm, with the DMLC tracking distributions showing generally good agreement between the planned and delivered doses.</p>}},
  author       = {{Pommer, Tobias and Falk, Marianne and Poulsen, Per R. and Keall, Paul J. and O'Brien, Ricky T. and Petersen, Peter Meidahl and Rosenschöld, Per Munck Af}},
  issn         = {{0031-9155}},
  language     = {{eng}},
  month        = {{04}},
  number       = {{7}},
  pages        = {{2349--2361}},
  publisher    = {{IOP Publishing}},
  series       = {{Physics in Medicine and Biology}},
  title        = {{Dosimetric benefit of DMLC tracking for conventional and sub-volume boosted prostate intensity-modulated arc radiotherapy}},
  url          = {{http://dx.doi.org/10.1088/0031-9155/58/7/2349}},
  doi          = {{10.1088/0031-9155/58/7/2349}},
  volume       = {{58}},
  year         = {{2013}},
}