Comparison of perimetric 24-2 and 30-2 test patterns in detecting visual field defects in patients with tumours in the pituitary region
(2024) In Acta Ophthalmologica 102(3). p.326-333- Abstract
PURPOSE: Automated perimetry provides a standardized method of measuring the visual field. The Humphrey Field Analyser (HFA) uses the 24-2 test pattern to cover 24 degrees centrally or the 30-2 test pattern to cover a slightly broader region of 30 degrees. The aim of this study was to determine whether the 24-2 test pattern provides comparable information to the 30-2 test pattern in detecting visual field defects in patients with tumours in the pituitary region.
METHODS: A retrospective cohort study was carried out on patients with tumours in the pituitary region and radiologically confirmed compression of the visual pathway. Included patients (79 of 133) had been examined using the Humphrey 30-2 visual field test, after which the... (More)
PURPOSE: Automated perimetry provides a standardized method of measuring the visual field. The Humphrey Field Analyser (HFA) uses the 24-2 test pattern to cover 24 degrees centrally or the 30-2 test pattern to cover a slightly broader region of 30 degrees. The aim of this study was to determine whether the 24-2 test pattern provides comparable information to the 30-2 test pattern in detecting visual field defects in patients with tumours in the pituitary region.
METHODS: A retrospective cohort study was carried out on patients with tumours in the pituitary region and radiologically confirmed compression of the visual pathway. Included patients (79 of 133) had been examined using the Humphrey 30-2 visual field test, after which the 30-2 test patterns were reduced into corresponding 24-2 test patterns. The location of visual field defects, visual acuity and the perimetric parameters mean deviation (MD) and visual field index (VFI) were also recorded.
RESULTS: No patient was classified differently when evaluated with the 24-2 test pattern, compared to the 30-2 test pattern. Interestingly, although the majority of patients had visual field defects located in the temporal visual field of each eye, a significant minority did not. In addition, it was found that a large proportion of patients had normal visual acuity (≥0.8).
CONCLUSIONS: The use of the HFA 24-2 test pattern reliably detected visual field defects in patients with tumours in the pituitary region. The present study indicates that MD and VFI are not reliable parameters for evaluating visual field defects due to compression.
(Less)
- author
- Gesslein, Bodil
LU
; Naumovska, Magdalena
LU
; Neumann, Olof
LU
; Bizios, Dimitrios
LU
; Bengtsson, Boel LU ; Siesjö, Peter LU
; Uvelius, Erik LU ; Hammar, Björn LU and Sheikh, Rafi LU
- organization
-
- Ophthalmology Imaging Research Group (research group)
- Ophthalmology, Lund
- LU Profile Area: Light and Materials
- Ophthalmology (Malmö) (research group)
- EpiHealth: Epidemiology for Health
- LUCC: Lund University Cancer Centre
- Glioma immunotherapy group (research group)
- Neurosurgery
- Clinical research in neuro-ophthalmology (research group)
- LTH Profile Area: Photon Science and Technology
- publishing date
- 2024-05
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Acta Ophthalmologica
- volume
- 102
- issue
- 3
- pages
- 8 pages
- publisher
- Wiley-Blackwell
- external identifiers
-
- pmid:37452447
- scopus:85165280481
- ISSN
- 1755-3768
- DOI
- 10.1111/aos.15731
- language
- English
- LU publication?
- yes
- additional info
- © 2023 The Authors. Acta Ophthalmologica published by John Wiley & Sons Ltd on behalf of Acta Ophthalmologica Scandinavica Foundation.
- id
- 8691331c-99aa-4d70-a50f-b39e8667c744
- date added to LUP
- 2023-07-22 10:52:56
- date last changed
- 2025-05-04 12:52:49
@article{8691331c-99aa-4d70-a50f-b39e8667c744, abstract = {{<p>PURPOSE: Automated perimetry provides a standardized method of measuring the visual field. The Humphrey Field Analyser (HFA) uses the 24-2 test pattern to cover 24 degrees centrally or the 30-2 test pattern to cover a slightly broader region of 30 degrees. The aim of this study was to determine whether the 24-2 test pattern provides comparable information to the 30-2 test pattern in detecting visual field defects in patients with tumours in the pituitary region.</p><p>METHODS: A retrospective cohort study was carried out on patients with tumours in the pituitary region and radiologically confirmed compression of the visual pathway. Included patients (79 of 133) had been examined using the Humphrey 30-2 visual field test, after which the 30-2 test patterns were reduced into corresponding 24-2 test patterns. The location of visual field defects, visual acuity and the perimetric parameters mean deviation (MD) and visual field index (VFI) were also recorded.</p><p>RESULTS: No patient was classified differently when evaluated with the 24-2 test pattern, compared to the 30-2 test pattern. Interestingly, although the majority of patients had visual field defects located in the temporal visual field of each eye, a significant minority did not. In addition, it was found that a large proportion of patients had normal visual acuity (≥0.8).</p><p>CONCLUSIONS: The use of the HFA 24-2 test pattern reliably detected visual field defects in patients with tumours in the pituitary region. The present study indicates that MD and VFI are not reliable parameters for evaluating visual field defects due to compression.</p>}}, author = {{Gesslein, Bodil and Naumovska, Magdalena and Neumann, Olof and Bizios, Dimitrios and Bengtsson, Boel and Siesjö, Peter and Uvelius, Erik and Hammar, Björn and Sheikh, Rafi}}, issn = {{1755-3768}}, language = {{eng}}, number = {{3}}, pages = {{326--333}}, publisher = {{Wiley-Blackwell}}, series = {{Acta Ophthalmologica}}, title = {{Comparison of perimetric 24-2 and 30-2 test patterns in detecting visual field defects in patients with tumours in the pituitary region}}, url = {{http://dx.doi.org/10.1111/aos.15731}}, doi = {{10.1111/aos.15731}}, volume = {{102}}, year = {{2024}}, }