Active chest tube clearance after aortic valve surgery did not influence amount residual pericardial fluid after aortic valve replacement in a randomised trial

Malgerud, Linnéa ; Maret, Eva ; Reitan, Christian LU and Ivert, Torbjörn (2020) In Scandinavian Cardiovascular Journal 54(3). p.200-205
Abstract

Objective. Evaluate if the use of active clearance of chest tubes after aortic valve surgery influenced bleeding and reduced postoperative residual pericardial effusion. Design. Prospective randomised trial comparing PleuraFlow® 32 F chest tube with FlowGlide™ active clearance to a standard Argyle® 32 F chest tube in 100 patients undergoing aortic valve surgery. Chest tube outputs and pericardial effusion measurements assessed by two-dimensional transthoracic echocardiography were recorded before hospital discharge. Results. Postoperative chest tube outputs per hour did not differ between the two groups. The median chest tube output was 400 mL for patients who had a PleuraFlow® chest tube vs. 490 mL for... (More)

Objective. Evaluate if the use of active clearance of chest tubes after aortic valve surgery influenced bleeding and reduced postoperative residual pericardial effusion. Design. Prospective randomised trial comparing PleuraFlow® 32 F chest tube with FlowGlide™ active clearance to a standard Argyle® 32 F chest tube in 100 patients undergoing aortic valve surgery. Chest tube outputs and pericardial effusion measurements assessed by two-dimensional transthoracic echocardiography were recorded before hospital discharge. Results. Postoperative chest tube outputs per hour did not differ between the two groups. The median chest tube output was 400 mL for patients who had a PleuraFlow® chest tube vs. 490 mL for patients with an Argyle® chest tube (p =.08). Pericardial effusions ≥ 2 mm were detected in 76% vs. 68% of the patients (p =.50) and postoperative atrial fibrillation occurred in 42% vs. 34% (p =.54), respectively. Conclusions. Use of active clearance chest tubes, compared to standard chest tubes after aortic valve surgery did not differ significantly regarding postoperative bleeding or degree of pericardial effusion as measured by echocardiography prior to hospital discharge.

(Less)
Please use this url to cite or link to this publication:
author
; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
active clearance, Aortic valve replacement, chest tubes, echocardiography, pericardial effusion
in
Scandinavian Cardiovascular Journal
volume
54
issue
3
pages
6 pages
publisher
Taylor & Francis
external identifiers
  • scopus:85080871542
  • pmid:32122153
ISSN
1401-7431
DOI
10.1080/14017431.2020.1728373
language
English
LU publication?
yes
id
898591e2-4626-418c-8d82-ce0457b65de9
date added to LUP
2020-03-24 16:10:05
date last changed
2024-05-29 11:10:15
@article{898591e2-4626-418c-8d82-ce0457b65de9,
  abstract     = {{<p>Objective. Evaluate if the use of active clearance of chest tubes after aortic valve surgery influenced bleeding and reduced postoperative residual pericardial effusion. Design. Prospective randomised trial comparing PleuraFlow<sup>®</sup> 32 F chest tube with FlowGlide™ active clearance to a standard Argyle<sup>®</sup> 32 F chest tube in 100 patients undergoing aortic valve surgery. Chest tube outputs and pericardial effusion measurements assessed by two-dimensional transthoracic echocardiography were recorded before hospital discharge. Results. Postoperative chest tube outputs per hour did not differ between the two groups. The median chest tube output was 400 mL for patients who had a PleuraFlow<sup>®</sup> chest tube vs. 490 mL for patients with an Argyle<sup>®</sup> chest tube (p =.08). Pericardial effusions ≥ 2 mm were detected in 76% vs. 68% of the patients (p =.50) and postoperative atrial fibrillation occurred in 42% vs. 34% (p =.54), respectively. Conclusions. Use of active clearance chest tubes, compared to standard chest tubes after aortic valve surgery did not differ significantly regarding postoperative bleeding or degree of pericardial effusion as measured by echocardiography prior to hospital discharge.</p>}},
  author       = {{Malgerud, Linnéa and Maret, Eva and Reitan, Christian and Ivert, Torbjörn}},
  issn         = {{1401-7431}},
  keywords     = {{active clearance; Aortic valve replacement; chest tubes; echocardiography; pericardial effusion}},
  language     = {{eng}},
  month        = {{03}},
  number       = {{3}},
  pages        = {{200--205}},
  publisher    = {{Taylor & Francis}},
  series       = {{Scandinavian Cardiovascular Journal}},
  title        = {{Active chest tube clearance after aortic valve surgery did not influence amount residual pericardial fluid after aortic valve replacement in a randomised trial}},
  url          = {{http://dx.doi.org/10.1080/14017431.2020.1728373}},
  doi          = {{10.1080/14017431.2020.1728373}},
  volume       = {{54}},
  year         = {{2020}},
}