(2021) ISMRM and SMRT Annual Meeting and Exhibition 2021 In Proc Intl Soc Magn Reson Med 29.- Abstract
 - Fitting the inversion recovery (IR) at multiple TI provides T1 estimates of high accuracy if performed in a single slice with full relaxation. We present anisotropic 3D variant based on MP-RAGE, where a T1-weighted driven equilibrium is prepared prior to inversion by a second RAGE readout. This abolishes the need for long recovery times and provides volumes of similar contrast for co-registration. The method was tested at 3T on a small cohort andcompared to 3D IR-TSE and 3D variable flip angle mapping.
 
    Please use this url to cite or link to this publication:
    https://lup.lub.lu.se/record/8c66f85c-7574-4758-ad15-44e6113e7afd
- author
 - 						Helms, Gunther
				LU
				
	 and 						Olsson, Hampus
				LU
	 - organization
 - publishing date
 - 2021-04-30
 - type
 - Chapter in Book/Report/Conference proceeding
 - publication status
 - published
 - subject
 - host publication
 - Proceedings of the 2021 ISMRM & ISMRT Annual Meeting and Exhibition
 - series title
 - Proc Intl Soc Magn Reson Med
 - volume
 - 29
 - article number
 - 3072
 - publisher
 - International Society for Magnetic Resonance in Medicine
 - conference name
 - ISMRM and SMRT Annual Meeting and Exhibition 2021
 - conference dates
 - 2021-05-15 - 2021-05-20
 - ISSN
 - 1545-4428
 - language
 - English
 - LU publication?
 - yes
 - id
 - 8c66f85c-7574-4758-ad15-44e6113e7afd
 - alternative location
 - https://index.mirasmart.com/ISMRM2021/PDFfiles/3072.html
 - date added to LUP
 - 2021-05-18 20:41:42
 - date last changed
 - 2025-04-04 14:19:00
 
@inproceedings{8c66f85c-7574-4758-ad15-44e6113e7afd,
  abstract     = {{Fitting the inversion recovery (IR) at multiple TI provides T<sub>1</sub> estimates of high accuracy if performed in a single slice with full relaxation. We present anisotropic 3D variant based on MP-RAGE, where a T1-weighted driven equilibrium is prepared prior to inversion by a second RAGE readout. This abolishes the need for long recovery times and provides volumes of similar contrast for co-registration. The method was tested at 3T on a small cohort andcompared to 3D IR-TSE and 3D variable flip angle mapping.}},
  author       = {{Helms, Gunther and Olsson, Hampus}},
  booktitle    = {{Proceedings of the 2021 ISMRM & ISMRT Annual Meeting and Exhibition}},
  issn         = {{1545-4428}},
  language     = {{eng}},
  month        = {{04}},
  publisher    = {{International Society for Magnetic Resonance in Medicine}},
  series       = {{Proc Intl Soc Magn Reson Med}},
  title        = {{Isotropic T<sub>1</sub>-mapping of the whole brain by MP-RAGE at different inversion times}},
  url          = {{https://index.mirasmart.com/ISMRM2021/PDFfiles/3072.html}},
  volume       = {{29}},
  year         = {{2021}},
}