Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Isotropic T1-mapping of the whole brain by MP-RAGE at different inversion times

Helms, Gunther LU orcid and Olsson, Hampus LU (2021) ISMRM and SMRT Annual Meeting and Exhibition 2021 In Proc Intl Soc Magn Reson Med 29.
Abstract
Fitting the inversion recovery (IR) at multiple TI provides T1 estimates of high accuracy if performed in a single slice with full relaxation. We present anisotropic 3D variant based on MP-RAGE, where a T1-weighted driven equilibrium is prepared prior to inversion by a second RAGE readout. This abolishes the need for long recovery times and provides volumes of similar contrast for co-registration. The method was tested at 3T on a small cohort andcompared to 3D IR-TSE and 3D variable flip angle mapping.
Please use this url to cite or link to this publication:
author
and
organization
publishing date
type
Chapter in Book/Report/Conference proceeding
publication status
published
subject
host publication
Proceedings of the 2021 ISMRM & ISMRT Annual Meeting and Exhibition
series title
Proc Intl Soc Magn Reson Med
volume
29
article number
3072
publisher
International Society for Magnetic Resonance in Medicine
conference name
ISMRM and SMRT Annual Meeting and Exhibition 2021
conference dates
2021-05-15 - 2021-05-20
ISSN
1545-4428
language
English
LU publication?
yes
id
8c66f85c-7574-4758-ad15-44e6113e7afd
alternative location
https://index.mirasmart.com/ISMRM2021/PDFfiles/3072.html
date added to LUP
2021-05-18 20:41:42
date last changed
2022-03-16 14:02:53
@inproceedings{8c66f85c-7574-4758-ad15-44e6113e7afd,
  abstract     = {{Fitting the inversion recovery (IR) at multiple TI provides T<sub>1</sub> estimates of high accuracy if performed in a single slice with full relaxation. We present anisotropic 3D variant based on MP-RAGE, where a T1-weighted driven equilibrium is prepared prior to inversion by a second RAGE readout. This abolishes the need for long recovery times and provides volumes of similar contrast for co-registration. The method was tested at 3T on a small cohort andcompared to 3D IR-TSE and 3D variable flip angle mapping.}},
  author       = {{Helms, Gunther and Olsson, Hampus}},
  booktitle    = {{Proceedings of the 2021 ISMRM & ISMRT Annual Meeting and Exhibition}},
  issn         = {{1545-4428}},
  language     = {{eng}},
  month        = {{04}},
  publisher    = {{International Society for Magnetic Resonance in Medicine}},
  series       = {{Proc Intl Soc Magn Reson Med}},
  title        = {{Isotropic T<sub>1</sub>-mapping of the whole brain by MP-RAGE at different inversion times}},
  url          = {{https://index.mirasmart.com/ISMRM2021/PDFfiles/3072.html}},
  volume       = {{29}},
  year         = {{2021}},
}