Cross-vendor transfer and RF coil comparison of a high-resolution MP2RAGE protocol for brain imaging at 7T

Helms, Gunther LU orcid ; Lätt, Jimmy LU and Olsson, Hampus LU (2020) 2020-001.
Abstract
An established MP2RAGE protocol for semi-quantitative structural brain MRI was transferred from one 7T MR scanner to that of another vendor featuring comparable hardware, but opposite polarity. On this system, the scan time could be reduced from 11 to 8 minutes, mainly by elliptical k-space sampling. Three configurations of radio-frequency (RF) transmission were compared (single channel with quadrature splitting, two and eight channels of fixed phase delays). Data processing for offline calculation MP2RAGE images is described in detail. The DICOM scaling of scanner B entails a loss of precision and accuracy and stronger artifacts in regions of low RF field, which can be improved by dielectric pads. For comparison and multi-site studies use... (More)
An established MP2RAGE protocol for semi-quantitative structural brain MRI was transferred from one 7T MR scanner to that of another vendor featuring comparable hardware, but opposite polarity. On this system, the scan time could be reduced from 11 to 8 minutes, mainly by elliptical k-space sampling. Three configurations of radio-frequency (RF) transmission were compared (single channel with quadrature splitting, two and eight channels of fixed phase delays). Data processing for offline calculation MP2RAGE images is described in detail. The DICOM scaling of scanner B entails a loss of precision and accuracy and stronger artifacts in regions of low RF field, which can be improved by dielectric pads. For comparison and multi-site studies use of an identical scan protocol and identical RF hardware is recommended. (Less)
Please use this url to cite or link to this publication:
author
; and
organization
alternative title
Cross-vendor transfer and RF coil comparison of a high-resolution MP2RAGE protocol for brain imaging at 7T
publishing date
type
Working paper/Preprint
publication status
published
subject
volume
2020-001
project
Multiparametric mapping of the brain at 7T using gradient echoes
Automated data pipeline for clinical quantitative 7T MRI
language
English
LU publication?
yes
id
8e0f852c-6aae-4d64-8667-910317cac6fb
alternative location
https://portal.research.lu.se/portal/files/79469556/ASL_2020_1_Helms_version3.pdf
date added to LUP
2020-05-28 10:55:38
date last changed
2022-03-16 14:05:46
@misc{8e0f852c-6aae-4d64-8667-910317cac6fb,
  abstract     = {{An established MP2RAGE protocol for semi-quantitative structural brain MRI was transferred from one 7T MR scanner to that of another vendor featuring comparable hardware, but opposite polarity. On this system, the scan time could be reduced from 11 to 8 minutes, mainly by elliptical k-space sampling. Three configurations of radio-frequency (RF) transmission were compared (single channel with quadrature splitting, two and eight channels of fixed phase delays). Data processing for offline calculation MP2RAGE images is described in detail. The DICOM scaling of scanner B entails a loss of precision and accuracy and stronger artifacts in regions of low RF field, which can be improved by dielectric pads. For comparison and multi-site studies use of an identical scan protocol and identical RF hardware is recommended.}},
  author       = {{Helms, Gunther and Lätt, Jimmy and Olsson, Hampus}},
  language     = {{eng}},
  note         = {{Working Paper}},
  title        = {{Cross-vendor transfer and RF coil comparison of a high-resolution MP2RAGE protocol for brain imaging at 7T}},
  url          = {{https://portal.research.lu.se/portal/files/79469556/ASL_2020_1_Helms_version3.pdf}},
  volume       = {{2020-001}},
  year         = {{2020}},
}