Estimation of patient doses from X-ray examinations in the Bryansk region hospitals

Vodovatov, Alexandr and Bernhardsson, Christian LU orcid (2013) Medical physics in the Baltic States 2013 p.133-136
Abstract
During 2012 - 2013 a study to evaluate conventional X-ray procedures and patient doses in Klintzi and Novozibkov areas of Bryansk region, Russia, was conducted. X-ray operation parameters included quality assurance of equipment, collection of procedure parameters and clinical practice evaluation. Effective doses were calculated for each selected procedure and dose distributions were established. 75-percentiles of the dose distributions were selected as a preliminary regional diagnostic reference levels (DRL). The DRLs were comparable to the St-Petersburg diagnostic reference levels, except for the skull, abdomen and pelvis areas. High dose spread is explained by differences in radiological practice and unit condition.
Please use this url to cite or link to this publication:
author
and
organization
publishing date
type
Chapter in Book/Report/Conference proceeding
publication status
published
subject
keywords
X-ray examinations, radiation protection, optimization, diagnostic reference level, effective dose
host publication
Medical Physics in the Baltic States : Proceedings of the 11th International Conference on Medical Physics - Proceedings of the 11th International Conference on Medical Physics
editor
Adliene, Diana
pages
4 pages
publisher
Kaunas University Of Technology Press
conference name
Medical physics in the Baltic States 2013
conference dates
2013-10-11 - 2013-10-12
ISSN
1822-5721
project
Radiation protection in Eastern Europe
language
English
LU publication?
yes
id
909c513f-a188-4241-9af5-9e70095a77d3 (old id 4092713)
alternative location
http://www.medphys.lt/medphys2013/
date added to LUP
2016-04-04 09:03:53
date last changed
2018-11-21 20:50:30
@inproceedings{909c513f-a188-4241-9af5-9e70095a77d3,
  abstract     = {{During 2012 - 2013 a study to evaluate conventional X-ray procedures and patient doses in Klintzi and Novozibkov areas of Bryansk region, Russia, was conducted. X-ray operation parameters included quality assurance of equipment, collection of procedure parameters and clinical practice evaluation. Effective doses were calculated for each selected procedure and dose distributions were established. 75-percentiles of the dose distributions were selected as a preliminary regional diagnostic reference levels (DRL). The DRLs were comparable to the St-Petersburg diagnostic reference levels, except for the skull, abdomen and pelvis areas. High dose spread is explained by differences in radiological practice and unit condition.}},
  author       = {{Vodovatov, Alexandr and Bernhardsson, Christian}},
  booktitle    = {{Medical Physics in the Baltic States : Proceedings of the 11th International Conference on Medical Physics}},
  editor       = {{Adliene, Diana}},
  issn         = {{1822-5721}},
  keywords     = {{X-ray examinations; radiation protection; optimization; diagnostic reference level; effective dose}},
  language     = {{eng}},
  pages        = {{133--136}},
  publisher    = {{Kaunas University Of Technology Press}},
  title        = {{Estimation of patient doses from X-ray examinations in the Bryansk region hospitals}},
  url          = {{https://lup.lub.lu.se/search/files/28716799/Vodovatov_and_Bernhardsson_2013_Estimation_of_patient_doses_from_x_ray_examinations_in_the_Bryansk_region_hospitals.pdf}},
  year         = {{2013}},
}