Validation of a rotational coherent anti-Stokes Raman spectroscopy model for carbon dioxide using high-resolution detection in the temperature range 294-1143 K
(2008) In Applied Optics 47(11). p.1893-1901- Abstract
- Experiments were performed in the temperature range of 294 - 1143 K in pure CO2 using high-resolution rotational coherent anti-Stokes Raman spectroscopy (CARS), in the dual-broadband approach. Experimental single-shot spectra were recorded with high spectral resolution using a single-mode Nd:YAG laser and a relay imaging lens system on the exit of a 1 m spectrometer. A theoretical rotational CARS model for CO, was developed for evaluation of the experimental spectra. The evaluated mean temperatures of the recorded single-shot dual-broadband rotational coherent anti-Stokes Raman spectroscopy (DB-RCARS) spectra using this model showed good agreement with thermocouple temperatures, and the relative standard deviation of evaluated single-shot... (More)
- Experiments were performed in the temperature range of 294 - 1143 K in pure CO2 using high-resolution rotational coherent anti-Stokes Raman spectroscopy (CARS), in the dual-broadband approach. Experimental single-shot spectra were recorded with high spectral resolution using a single-mode Nd:YAG laser and a relay imaging lens system on the exit of a 1 m spectrometer. A theoretical rotational CARS model for CO, was developed for evaluation of the experimental spectra. The evaluated mean temperatures of the recorded single-shot dual-broadband rotational coherent anti-Stokes Raman spectroscopy (DB-RCARS) spectra using this model showed good agreement with thermocouple temperatures, and the relative standard deviation of evaluated single-shot temperatures was generally 2 - 3%. Simultaneous thermometry and relative CO2/N-2-concentration measurements were demonstrated in the product gas of premixed laminar CO/air flames at atmospheric pressure. Although the model proved to be accurate for thermometry up to 1143 K, limitations were observed at flame temperatures where temperatures were overestimated and relative CO2/N-2 concentrations were underestimated. Potential sources for these discrepancies are discussed. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/1205387
- author
- Vestin, Fredrik LU ; Nilsson, Kristin and Bengtsson, Per-Erik LU
- organization
- publishing date
- 2008
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Applied Optics
- volume
- 47
- issue
- 11
- pages
- 1893 - 1901
- publisher
- Optical Society of America
- external identifiers
-
- wos:000255492100024
- scopus:51649094617
- ISSN
- 2155-3165
- DOI
- 10.1364/AO.47.001893
- language
- English
- LU publication?
- yes
- id
- 91684681-5ccb-47db-ac54-2180fb4008c3 (old id 1205387)
- date added to LUP
- 2016-04-01 12:11:28
- date last changed
- 2022-01-27 00:04:18
@article{91684681-5ccb-47db-ac54-2180fb4008c3, abstract = {{Experiments were performed in the temperature range of 294 - 1143 K in pure CO2 using high-resolution rotational coherent anti-Stokes Raman spectroscopy (CARS), in the dual-broadband approach. Experimental single-shot spectra were recorded with high spectral resolution using a single-mode Nd:YAG laser and a relay imaging lens system on the exit of a 1 m spectrometer. A theoretical rotational CARS model for CO, was developed for evaluation of the experimental spectra. The evaluated mean temperatures of the recorded single-shot dual-broadband rotational coherent anti-Stokes Raman spectroscopy (DB-RCARS) spectra using this model showed good agreement with thermocouple temperatures, and the relative standard deviation of evaluated single-shot temperatures was generally 2 - 3%. Simultaneous thermometry and relative CO2/N-2-concentration measurements were demonstrated in the product gas of premixed laminar CO/air flames at atmospheric pressure. Although the model proved to be accurate for thermometry up to 1143 K, limitations were observed at flame temperatures where temperatures were overestimated and relative CO2/N-2 concentrations were underestimated. Potential sources for these discrepancies are discussed.}}, author = {{Vestin, Fredrik and Nilsson, Kristin and Bengtsson, Per-Erik}}, issn = {{2155-3165}}, language = {{eng}}, number = {{11}}, pages = {{1893--1901}}, publisher = {{Optical Society of America}}, series = {{Applied Optics}}, title = {{Validation of a rotational coherent anti-Stokes Raman spectroscopy model for carbon dioxide using high-resolution detection in the temperature range 294-1143 K}}, url = {{http://dx.doi.org/10.1364/AO.47.001893}}, doi = {{10.1364/AO.47.001893}}, volume = {{47}}, year = {{2008}}, }