An automatic perimeter for glaucoma visual field screening and control. Construction and clinical cases
(1975) In Albrecht von Graefes Archiv für Klinische und Experimentelle Ophthalmologie 197(1). p.13-23- Abstract
An apparatus for static perimetry of the central visual field at 64 points is described. The testing is fully automatic: the test logic is programmed into a mini-computer and the results are plotted as a diagram in polar coordinates. A few cases with small or medium sized visual field defects have been analyzed by conventional methods and by the automatic instrument with satisfying results.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/930c4136-5fe4-49de-87e5-24abd434165d
- author
- Heijl, A LU and Krakau, C E
- organization
- publishing date
- 1975-10-17
- type
- Contribution to journal
- publication status
- published
- keywords
- Adult, Aged, Electronic Data Processing, Electronics, Medical, Glaucoma/diagnosis, Humans, Middle Aged, Visual Field Tests/methods, Visual Fields
- in
- Albrecht von Graefes Archiv für Klinische und Experimentelle Ophthalmologie
- volume
- 197
- issue
- 1
- pages
- 11 pages
- publisher
- Springer
- external identifiers
-
- pmid:1081847
- scopus:0016804809
- ISSN
- 0065-6100
- DOI
- 10.1007/BF00506636
- language
- English
- LU publication?
- yes
- id
- 930c4136-5fe4-49de-87e5-24abd434165d
- date added to LUP
- 2019-06-30 19:31:04
- date last changed
- 2024-01-01 14:47:24
@article{930c4136-5fe4-49de-87e5-24abd434165d, abstract = {{<p>An apparatus for static perimetry of the central visual field at 64 points is described. The testing is fully automatic: the test logic is programmed into a mini-computer and the results are plotted as a diagram in polar coordinates. A few cases with small or medium sized visual field defects have been analyzed by conventional methods and by the automatic instrument with satisfying results.</p>}}, author = {{Heijl, A and Krakau, C E}}, issn = {{0065-6100}}, keywords = {{Adult; Aged; Electronic Data Processing; Electronics, Medical; Glaucoma/diagnosis; Humans; Middle Aged; Visual Field Tests/methods; Visual Fields}}, language = {{eng}}, month = {{10}}, number = {{1}}, pages = {{13--23}}, publisher = {{Springer}}, series = {{Albrecht von Graefes Archiv für Klinische und Experimentelle Ophthalmologie}}, title = {{An automatic perimeter for glaucoma visual field screening and control. Construction and clinical cases}}, url = {{http://dx.doi.org/10.1007/BF00506636}}, doi = {{10.1007/BF00506636}}, volume = {{197}}, year = {{1975}}, }